SubjectRe: [PATCH v10 5/8] IMA: limit critical data measurement based on a label
From
Date


On 2021-01-13 6:09 p.m., Mimi Zohar wrote:
> On Thu, 2021-01-07 at 20:07 -0800, Tushar Sugandhi wrote:
>> Integrity critical data may belong to a single subsystem or it may
>> arise from cross subsystem interaction. Currently there is no mechanism
>> to group or limit the data based on certain label. Limiting and
>> grouping critical data based on a label would make it flexible and
>> configurable to measure.
>>
>> Define "label:=", a new IMA policy condition, for the IMA func
>> CRITICAL_DATA to allow grouping and limiting measurement of integrity
>> critical data.
>>
>> Limit the measurement to the labels that are specified in the IMA
>> policy - CRITICAL_DATA+"label:=". If "label:=" is not provided with
>> the func CRITICAL_DATA, measure all the input integrity critical data.
>>
>> Signed-off-by: Tushar Sugandhi <tusharsu@linux.microsoft.com>
>> Reviewed-by: Tyler Hicks <tyhicks@linux.microsoft.com>
>
> This is looking a lot better.
>
> thanks,
>
> Mimi
>
Thanks a lot for the feedback Mimi.
Appreciate it. :)

~Tushar

\
 
 \ /