| Subject | Re: [PATCH 11/19] gdrom: use bdev_check_media_change | From | Hannes Reinecke <> | Date | Wed, 9 Sep 2020 09:27:02 +0200 |
| |
On 9/8/20 4:53 PM, Christoph Hellwig wrote: > The Sega GD-ROM driver does not have a ->revalidate_disk method, so it > can just use bdev_check_media_change without any additional changes. > > Signed-off-by: Christoph Hellwig <hch@lst.de> > Reviewed-by: Johannes Thumshirn <johannes.thumshirn@wdc.com> > --- > drivers/cdrom/gdrom.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/cdrom/gdrom.c b/drivers/cdrom/gdrom.c > index 09b0cd292720fa..9874fc1c815b53 100644 > --- a/drivers/cdrom/gdrom.c > +++ b/drivers/cdrom/gdrom.c > @@ -479,7 +479,7 @@ static int gdrom_bdops_open(struct block_device *bdev, fmode_t mode) > { > int ret; > > - check_disk_change(bdev); > + bdev_check_media_change(bdev); > > mutex_lock(&gdrom_mutex); > ret = cdrom_open(gd.cd_info, bdev, mode); > Reviewed-by: Hannes Reinecke <hare@suse.de>
Cheers,
Hannes -- Dr. Hannes Reinecke Kernel Storage Architect hare@suse.de +49 911 74053 688 SUSE Software Solutions Germany GmbH, Maxfeldstr. 5, 90409 Nürnberg HRB 36809 (AG Nürnberg), GF: Felix Imendörffer
|