On 7/26/20 6:24 PM, Sebastian Reichel wrote:
> Hi,
>
> On Mon, Jul 20, 2020 at 03:43:58PM -0500, Ricardo Rivera-Matos wrote:
>> From: Dan Murphy <dmurphy@ti.com>
>>
>> Convert the battery.txt file to yaml and fix up the examples.
> The examples were correct for the existing binding. What you did
> is completly changing the binding description (without modifying
> the code) resulting in examples and any existing users being
> incorrect and code not matching up with the binding.
ACK
>
>> Signed-off-by: Dan Murphy <dmurphy@ti.com>
>> ---
>> .../bindings/power/supply/battery.txt | 86 +---------
>> .../bindings/power/supply/battery.yaml | 157 ++++++++++++++++++
>> 2 files changed, 158 insertions(+), 85 deletions(-)
>> create mode 100644 Documentation/devicetree/bindings/power/supply/battery.yaml
>>
>> diff --git a/Documentation/devicetree/bindings/power/supply/battery.txt b/Documentation/devicetree/bindings/power/supply/battery.txt
>> index 5e29595edd74..a9f80cc49068 100644
>> --- a/Documentation/devicetree/bindings/power/supply/battery.txt
>> +++ b/Documentation/devicetree/bindings/power/supply/battery.txt
>> @@ -1,87 +1,3 @@
>> -Battery Characteristics
>> -
>> -The devicetree battery node provides static battery characteristics.
>> -In smart batteries, these are typically stored in non-volatile memory
>> -on a fuel gauge chip. The battery node should be used where there is
>> -no appropriate non-volatile memory, or it is unprogrammed/incorrect.
>> -
>> -Upstream dts files should not include battery nodes, unless the battery
>> -represented cannot easily be replaced in the system by one of a
>> -different type. This prevents unpredictable, potentially harmful,
>> -behavior should a replacement that changes the battery type occur
>> -without a corresponding update to the dtb.
>> +The contents of this file has been moved to battery.yaml
>>
>> Please note that not all charger drivers respect all of the properties.
>> -
>> -Required Properties:
>> - - compatible: Must be "simple-battery"
>> -
>> -Optional Properties:
>> - - over-voltage-threshold-microvolt: battery over-voltage limit
>> - - re-charge-voltage-microvolt: limit to automatically start charging again
>> - - voltage-min-design-microvolt: drained battery voltage
>> - - voltage-max-design-microvolt: fully charged battery voltage
>> - - energy-full-design-microwatt-hours: battery design energy
>> - - charge-full-design-microamp-hours: battery design capacity
>> - - trickle-charge-current-microamp: current for trickle-charge phase
>> - - precharge-current-microamp: current for pre-charge phase
>> - - precharge-upper-limit-microvolt: limit when to change to constant charging
>> - - charge-term-current-microamp: current for charge termination phase
>> - - constant-charge-current-max-microamp: maximum constant input current
>> - - constant-charge-voltage-max-microvolt: maximum constant input voltage
>> - - factory-internal-resistance-micro-ohms: battery factory internal resistance
>> - - ocv-capacity-table-0: An array providing the open circuit voltage (OCV)
>> - of the battery and corresponding battery capacity percent, which is used
>> - to look up battery capacity according to current OCV value. And the open
>> - circuit voltage unit is microvolt.
>> - - ocv-capacity-table-1: Same as ocv-capacity-table-0
>> - ......
>> - - ocv-capacity-table-n: Same as ocv-capacity-table-0
>> - - ocv-capacity-celsius: An array containing the temperature in degree Celsius,
>> - for each of the battery capacity lookup table. The first temperature value
>> - specifies the OCV table 0, and the second temperature value specifies the
>> - OCV table 1, and so on.
>> - - resistance-temp-table: An array providing the temperature in degree Celsius
>> - and corresponding battery internal resistance percent, which is used to look
>> - up the resistance percent according to current temperature to get a accurate
>> - batterty internal resistance in different temperatures.
>> -
>> -Battery properties are named, where possible, for the corresponding
>> -elements in enum power_supply_property, defined in
>> -https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/include/linux/power_supply.h
>> -
>> -Batteries must be referenced by chargers and/or fuel-gauges
>> -using a phandle. The phandle's property should be named
>> -"monitored-battery".
>> -
>> -Example:
>> -
>> - bat: battery {
>> - compatible = "simple-battery";
>> - voltage-min-design-microvolt = <3200000>;
>> - voltage-max-design-microvolt = <4200000>;
>> - energy-full-design-microwatt-hours = <5290000>;
>> - charge-full-design-microamp-hours = <1430000>;
>> - precharge-current-microamp = <256000>;
>> - charge-term-current-microamp = <128000>;
>> - constant-charge-current-max-microamp = <900000>;
>> - constant-charge-voltage-max-microvolt = <4200000>;
>> - factory-internal-resistance-micro-ohms = <250000>;
>> - ocv-capacity-celsius = <(-10) 0 10>;
>> - ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...;
>> - ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...;
>> - ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...;
>> - resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
>> - };
>> -
>> - charger: charger@11 {
>> - ....
>> - monitored-battery = <&bat>;
>> - ...
>> - };
>> -
>> - fuel_gauge: fuel-gauge@22 {
>> - ....
>> - monitored-battery = <&bat>;
>> - ...
>> - };
>> diff --git a/Documentation/devicetree/bindings/power/supply/battery.yaml b/Documentation/devicetree/bindings/power/supply/battery.yaml
>> new file mode 100644
>> index 000000000000..d7a2380b46f9
>> --- /dev/null
>> +++ b/Documentation/devicetree/bindings/power/supply/battery.yaml
>> @@ -0,0 +1,157 @@
>> +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
>> +%YAML 1.2
>> +---
>> +$id: http://devicetree.org/schemas/power/supply/battery.yaml#
>> +$schema: http://devicetree.org/meta-schemas/core.yaml#
>> +
>> +title: Battery Characteristics
>> +
>> +maintainers:
>> + - Sebastian Reichel <sre@kernel.org>
>> +
>> +description: |
>> + The devicetree battery node provides static battery characteristics.
>> + In smart batteries, these are typically stored in non-volatile memory
>> + on a fuel gauge chip. The battery node should be used where there is
>> + no appropriate non-volatile memory, or it is unprogrammed/incorrect.
>> +
>> + Upstream dts files should not include battery nodes, unless the battery
>> + represented cannot easily be replaced in the system by one of a
>> + different type. This prevents unpredictable, potentially harmful,
>> + behavior should a replacement that changes the battery type occur
>> + without a corresponding update to the dtb.
>> +
>> + Battery properties are named, where possible, for the corresponding elements
>> + in enum power_supply_property, defined in include/linux/power_supply.h
>> +
>> + Batteries must be referenced by chargers and/or fuel-gauges using a phandle.
>> + The phandle's property should be named "monitored-battery".
>> +
>> +properties:
>> + compatible:
>> + const: simple-battery
>> +
>> + over-voltage-threshold-microvolt:
>> + description: battery over-voltage limit
>> +
>> + re-charge-voltage-microvolt:
>> + description: limit to automatically start charging again
>> +
>> + voltage-min-design-microvolt:
>> + description: drained battery voltage
>> +
>> + voltage-max-design-microvolt:
>> + description: fully charged battery voltage
>> +
>> + energy-full-design-microwatt-hours:
>> + description: battery design energy
>> +
>> + charge-full-design-microamp-hours:
>> + description: battery design capacity
>> +
>> + trickle-charge-current-microamp:
>> + description: current for trickle-charge phase
>> +
>> + precharge-current-microamp:
>> + description: current for pre-charge phase
>> +
>> + precharge-upper-limit-microvolt:
>> + description: limit when to change to constant charging
>> +
>> + charge-term-current-microamp:
>> + description: current for charge termination phase
>> +
>> + constant-charge-current-max-microamp:
>> + description: maximum constant input current
>> +
>> + constant-charge-voltage-max-microvolt:
>> + description: maximum constant input voltage
>> +
>> + factory-internal-resistance-micro-ohms:
>> + description: battery factory internal resistance
>> +
>> + monitored-battery:
>> + $ref: /schemas/types.yaml#/definitions/phandle
>> + description: phandle to the battery node being monitored
> monitored-battery is not a valid property of simple-battery node
> (the one having compatible = "simple-battery"). It needs to be
> listed in the binding _using_ simple-battery (which you did in
> the bq2515x binding). Drop it.
ACK
>
>> +required:
>> + - compatible
>> +
>> +patternProperties:
>> + '^ocv-capacity-table-[0-100]$':
>> + $ref: /schemas/types.yaml#/definitions/uint32-matrix
>> + description: |
>> + An array providing the open circuit voltage (OCV)
>> + of the battery and corresponding battery capacity percent, which is used
>> + to look up battery capacity according to current OCV value. And the open
>> + circuit voltage unit is microvolt.
>> + maxItems: 100
>> + items:
>> + items:
>> + - description: open circuit voltage (OCV) in microvolts
>> + - description: battery capacity percent
>> + maximum: 100
> This looks ok.
Sounds good
>
>> + '^resistance-temp-table-[0-100]$':
>> + $ref: /schemas/types.yaml#/definitions/uint32-matrix
>> + description: |
>> + An array providing the temperature in degree Celsius
>> + and corresponding battery internal resistance percent, which is used to
>> + look up the resistance percent according to current temperature to get an
>> + accurate batterty internal resistance in different temperatures.
>> + maxItems: 100
>> + items:
>> + items:
>> + - description: internal resistance percent
>> + - description: battery capacity percent
>> + maximum: 100
> This is a single property ("resistance-temp-table") describing
> a graph with temperature on one axis and battery internal resistance
> on the other axis. The first cell is temperature in degree Celsius
> and the second cell is internal resistance percentage. So old
> example
>
> resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
>
> translates into
>
> 20° => 100% of "factory-internal-resistance-micro-ohms"
> 10° => 90% of "factory-internal-resistance-micro-ohms"
Okay thanks for explaining this.
>
>> + '^ocv-capacity-celsius-[0-100]$':
>> + $ref: /schemas/types.yaml#/definitions/uint32-matrix
>> + description: |
>> + An array containing the temperature in degree Celsius,
>> + for each of the battery capacity lookup table.
>> + maxItems: 100
>> + items:
>> + items:
>> + - description: temperature in degree Celsius
>> + - description: battery capacity percent
>> + maximum: 100
> This is also incorrect. This is a single property ("ocv-capacity-celsius"),
> which is the lookup table for "^ocv-capacity-table-[0-100]$". It maps
> ocv-capacity tables to temperatures. Let me use the example from the
> old *.txt binding again:
>
> ocv-capacity-celsius = <(-10) 0 10>;
> ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...;
> ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...;
> ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...;
>
> -10 degree Celsius is index 0, so ocv-capacity-table-0 should be
> used for -10 degrees Celsius.
>
> 0 degrees Celsius is index 1, so ocv-capacity-table-1 should
> be used for this temperature.
>
> 10 degrees Celsius is index 2, so ocv-capacity-table-2
> should be used for this temperature.
ACK
>
> -- Sebastian
>
>> +additionalProperties: false
>> +
>> +examples:
>> + - |
>> + power {
>> + #address-cells = <1>;
>> + #size-cells = <0>;
>> +
>> + battery: battery {
>> + compatible = "simple-battery";
>> + over-voltage-threshold-microvolt = <4500000>;
>> + re-charge-voltage-microvolt = <250000>;
>> + voltage-min-design-microvolt = <3200000>;
>> + voltage-max-design-microvolt = <4200000>;
>> + energy-full-design-microwatt-hours = <5290000>;
>> + charge-full-design-microamp-hours = <1430000>;
>> + precharge-current-microamp = <256000>;
>> + precharge-upper-limit-microvolt = <2500000>;
>> + charge-term-current-microamp = <128000>;
>> + constant-charge-current-max-microamp = <900000>;
>> + constant-charge-voltage-max-microvolt = <4200000>;
>> + factory-internal-resistance-micro-ohms = <250000>;
>> + ocv-capacity-celsius-0 = <(-10) 10>;
>> + ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>;
>> + resistance-temp-table-0 = <20 100>, <10 90>, <0 80>, <(-10) 60>;
>> + };
>> +
>> + charger@11 {
>> + reg = <0x11>;
>> + monitored-battery = <&battery>;
>> + };
>> +
>> + fuel-gauge@22 {
>> + reg = <0x22>;
>> + monitored-battery = <&battery>;
>> + };
>> + };
>> --
>> 2.27.0

\
 
 \ /
  Last update: 2020-07-27 20:18    [W:0.059 / U:2.132 seconds]