Subject[PATCH] dt-bindings: thermal: Get rid of thermal.txt and replace references
Date
Now that we have yaml bindings for the thermal subsystem, get rid of the
old bindings (thermal.txt).

Replace all references to thermal.txt in the Documentation with a link
to the appropriate YAML bindings using the following search and replace
pattern:
- If the reference is specific to the thermal-sensor-cells property,
replace with a pointer to thermal-sensor.yaml
- If the reference is to the cooling-cells property, replace with a
pointer to thermal-cooling-devices.yaml
- If the reference is generic thermal bindings, replace with a
reference to thermal*.yaml.

Signed-off-by: Amit Kucheria <amit.kucheria@linaro.org>
---
Changes since v1:
- Rebase onto v.5.8-rc6 to make it apply again
- Fix cpufreq/nvidia,tegra20-cpufreq.txt
- Fix bindings/arm/freescale/fsl,scu.txt


.../devicetree/bindings/arm/arm,scmi.txt | 2 +-
.../devicetree/bindings/arm/arm,scpi.txt | 2 +-
.../bindings/arm/freescale/fsl,scu.txt | 2 +-
.../arm/marvell/ap80x-system-controller.txt | 2 +-
.../arm/marvell/cp110-system-controller.txt | 2 +-
.../bindings/cpufreq/cpufreq-dt.txt | 3 +-
.../bindings/cpufreq/cpufreq-mediatek.txt | 4 +-
.../cpufreq/nvidia,tegra20-cpufreq.txt | 2 +-
.../devicetree/bindings/hwmon/gpio-fan.txt | 3 +-
.../devicetree/bindings/hwmon/lm90.txt | 4 +-
.../thermal/allwinner,sun8i-a83t-ths.yaml | 2 +-
.../bindings/thermal/amazon,al-thermal.txt | 2 +-
.../bindings/thermal/brcm,avs-ro-thermal.yaml | 2 +-
.../bindings/thermal/brcm,bcm2835-thermal.txt | 2 +-
.../bindings/thermal/hisilicon-thermal.txt | 2 +-
.../bindings/thermal/max77620_thermal.txt | 6 +-
.../bindings/thermal/mediatek-thermal.txt | 2 +-
.../thermal/nvidia,tegra124-soctherm.txt | 10 +-
.../thermal/nvidia,tegra186-bpmp-thermal.txt | 2 +-
.../bindings/thermal/qcom-spmi-temp-alarm.txt | 2 +-
.../bindings/thermal/rockchip-thermal.txt | 2 +-
.../bindings/thermal/tango-thermal.txt | 2 +-
.../bindings/thermal/thermal-generic-adc.txt | 2 +-
.../devicetree/bindings/thermal/thermal.txt | 586 ------------------
24 files changed, 34 insertions(+), 616 deletions(-)
delete mode 100644 Documentation/devicetree/bindings/thermal/thermal.txt

diff --git a/Documentation/devicetree/bindings/arm/arm,scmi.txt b/Documentation/devicetree/bindings/arm/arm,scmi.txt
index 1f293ea24cd85..55deb68230ebb 100644
--- a/Documentation/devicetree/bindings/arm/arm,scmi.txt
+++ b/Documentation/devicetree/bindings/arm/arm,scmi.txt
@@ -102,7 +102,7 @@ Required sub-node properties:
[0] http://infocenter.arm.com/help/topic/com.arm.doc.den0056a/index.html
[1] Documentation/devicetree/bindings/clock/clock-bindings.txt
[2] Documentation/devicetree/bindings/power/power-domain.yaml
-[3] Documentation/devicetree/bindings/thermal/thermal.txt
+[3] Documentation/devicetree/bindings/thermal/thermal*.yaml
[4] Documentation/devicetree/bindings/sram/sram.yaml
[5] Documentation/devicetree/bindings/reset/reset.txt

diff --git a/Documentation/devicetree/bindings/arm/arm,scpi.txt b/Documentation/devicetree/bindings/arm/arm,scpi.txt
index dd04d9d9a1b8e..bcd6c3ec471e6 100644
--- a/Documentation/devicetree/bindings/arm/arm,scpi.txt
+++ b/Documentation/devicetree/bindings/arm/arm,scpi.txt
@@ -108,7 +108,7 @@ Required properties:

[0] http://infocenter.arm.com/help/topic/com.arm.doc.dui0922b/index.html
[1] Documentation/devicetree/bindings/clock/clock-bindings.txt
-[2] Documentation/devicetree/bindings/thermal/thermal.txt
+[2] Documentation/devicetree/bindings/thermal/thermal*.yaml
[3] Documentation/devicetree/bindings/sram/sram.yaml
[4] Documentation/devicetree/bindings/power/power-domain.yaml

diff --git a/Documentation/devicetree/bindings/arm/freescale/fsl,scu.txt b/Documentation/devicetree/bindings/arm/freescale/fsl,scu.txt
index 10b8459e49f8c..6064d98b10314 100644
--- a/Documentation/devicetree/bindings/arm/freescale/fsl,scu.txt
+++ b/Documentation/devicetree/bindings/arm/freescale/fsl,scu.txt
@@ -176,7 +176,7 @@ Required properties:
"fsl,imx8qxp-sc-thermal"
followed by "fsl,imx-sc-thermal";

-- #thermal-sensor-cells: See Documentation/devicetree/bindings/thermal/thermal.txt
+- #thermal-sensor-cells: See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml
for a description.

Example (imx8qxp):
diff --git a/Documentation/devicetree/bindings/arm/marvell/ap80x-system-controller.txt b/Documentation/devicetree/bindings/arm/marvell/ap80x-system-controller.txt
index 098d932fc9630..e31511255d8e3 100644
--- a/Documentation/devicetree/bindings/arm/marvell/ap80x-system-controller.txt
+++ b/Documentation/devicetree/bindings/arm/marvell/ap80x-system-controller.txt
@@ -111,7 +111,7 @@ Thermal:
--------

For common binding part and usage, refer to
-Documentation/devicetree/bindings/thermal/thermal.txt
+Documentation/devicetree/bindings/thermal/thermal*.yaml

The thermal IP can probe the temperature all around the processor. It
may feature several channels, each of them wired to one sensor.
diff --git a/Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt b/Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt
index f982a8ed93968..a21f7709596c0 100644
--- a/Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt
+++ b/Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt
@@ -203,7 +203,7 @@ It is possible to setup an overheat interrupt by giving at least one
critical point to any subnode of the thermal-zone node.

For common binding part and usage, refer to
-Documentation/devicetree/bindings/thermal/thermal.txt
+Documentation/devicetree/bindings/thermal/thermal*.yaml

Required properties:
- compatible: must be one of:
diff --git a/Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt b/Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt
index 332aed8f4597a..56f4423743838 100644
--- a/Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt
+++ b/Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt
@@ -18,7 +18,8 @@ Optional properties:
in unit of nanoseconds.
- voltage-tolerance: Specify the CPU voltage tolerance in percentage.
- #cooling-cells:
- Please refer to Documentation/devicetree/bindings/thermal/thermal.txt.
+ Please refer to
+ Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml.

Examples:

diff --git a/Documentation/devicetree/bindings/cpufreq/cpufreq-mediatek.txt b/Documentation/devicetree/bindings/cpufreq/cpufreq-mediatek.txt
index 0551c78619de8..ea4994b35207d 100644
--- a/Documentation/devicetree/bindings/cpufreq/cpufreq-mediatek.txt
+++ b/Documentation/devicetree/bindings/cpufreq/cpufreq-mediatek.txt
@@ -21,8 +21,8 @@ Optional properties:
flow is handled by hardware, hence no software "voltage tracking" is
needed.
- #cooling-cells:
- Please refer to Documentation/devicetree/bindings/thermal/thermal.txt
- for detail.
+ For details, please refer to
+ Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml

Example 1 (MT7623 SoC):

diff --git a/Documentation/devicetree/bindings/cpufreq/nvidia,tegra20-cpufreq.txt b/Documentation/devicetree/bindings/cpufreq/nvidia,tegra20-cpufreq.txt
index daeca6ae6b769..52a24b82fd864 100644
--- a/Documentation/devicetree/bindings/cpufreq/nvidia,tegra20-cpufreq.txt
+++ b/Documentation/devicetree/bindings/cpufreq/nvidia,tegra20-cpufreq.txt
@@ -5,7 +5,7 @@ Required properties:
- clocks: Must contain an entry for the CPU clock.
See ../clocks/clock-bindings.txt for details.
- operating-points-v2: See ../bindings/opp/opp.txt for details.
-- #cooling-cells: Should be 2. See ../thermal/thermal.txt for details.
+- #cooling-cells: Should be 2. See ../thermal/thermal-cooling-devices.yaml for details.

For each opp entry in 'operating-points-v2' table:
- opp-supported-hw: Two bitfields indicating:
diff --git a/Documentation/devicetree/bindings/hwmon/gpio-fan.txt b/Documentation/devicetree/bindings/hwmon/gpio-fan.txt
index 2becdcfdc840c..f4cfa350f6a14 100644
--- a/Documentation/devicetree/bindings/hwmon/gpio-fan.txt
+++ b/Documentation/devicetree/bindings/hwmon/gpio-fan.txt
@@ -12,7 +12,8 @@ Optional properties:
- alarm-gpios: This pin going active indicates something is wrong with
the fan, and a udev event will be fired.
- #cooling-cells: If used as a cooling device, must be <2>
- Also see: Documentation/devicetree/bindings/thermal/thermal.txt
+ Also see:
+ Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml
min and max states are derived from the speed-map of the fan.

Note: At least one the "gpios" or "alarm-gpios" properties must be set.
diff --git a/Documentation/devicetree/bindings/hwmon/lm90.txt b/Documentation/devicetree/bindings/hwmon/lm90.txt
index c76a7ac47c342..398dcb9657514 100644
--- a/Documentation/devicetree/bindings/hwmon/lm90.txt
+++ b/Documentation/devicetree/bindings/hwmon/lm90.txt
@@ -34,8 +34,8 @@ Optional properties:
LM90 "-ALERT" pin output.
See interrupt-controller/interrupts.txt for the format.

-- #thermal-sensor-cells: should be set to 1. See thermal/thermal.txt for
- details. See <include/dt-bindings/thermal/lm90.h> for the
+- #thermal-sensor-cells: should be set to 1. See thermal/thermal-sensor.yaml
+ for details. See <include/dt-bindings/thermal/lm90.h> for the
definition of the local, remote and 2nd remote sensor index
constants.

diff --git a/Documentation/devicetree/bindings/thermal/allwinner,sun8i-a83t-ths.yaml b/Documentation/devicetree/bindings/thermal/allwinner,sun8i-a83t-ths.yaml
index 87369264feb96..44ba6765697d8 100644
--- a/Documentation/devicetree/bindings/thermal/allwinner,sun8i-a83t-ths.yaml
+++ b/Documentation/devicetree/bindings/thermal/allwinner,sun8i-a83t-ths.yaml
@@ -50,7 +50,7 @@ properties:
nvmem-cell-names:
const: calibration

- # See ./thermal.txt for details
+ # See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for details
"#thermal-sensor-cells":
enum:
- 0
diff --git a/Documentation/devicetree/bindings/thermal/amazon,al-thermal.txt b/Documentation/devicetree/bindings/thermal/amazon,al-thermal.txt
index 703979dbd577d..12fc4ef04837f 100644
--- a/Documentation/devicetree/bindings/thermal/amazon,al-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/amazon,al-thermal.txt
@@ -6,7 +6,7 @@ transaction.
Required properties:
- compatible: "amazon,al-thermal".
- reg: The physical base address and length of the sensor's registers.
-- #thermal-sensor-cells: Must be 1. See ./thermal.txt for a description.
+- #thermal-sensor-cells: Must be 1. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for a description.

Example:
thermal: thermal {
diff --git a/Documentation/devicetree/bindings/thermal/brcm,avs-ro-thermal.yaml b/Documentation/devicetree/bindings/thermal/brcm,avs-ro-thermal.yaml
index f3e68ed03abf8..1ab5070c751d5 100644
--- a/Documentation/devicetree/bindings/thermal/brcm,avs-ro-thermal.yaml
+++ b/Documentation/devicetree/bindings/thermal/brcm,avs-ro-thermal.yaml
@@ -23,7 +23,7 @@ properties:
compatible:
const: brcm,bcm2711-thermal

- # See ./thermal.txt for details
+ # See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for details
"#thermal-sensor-cells":
const: 0

diff --git a/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt b/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt
index da8c5b73ad105..a3e9ec5dc7ac4 100644
--- a/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt
@@ -7,7 +7,7 @@ compatible: should be one of: "brcm,bcm2835-thermal",
"brcm,bcm2836-thermal" or "brcm,bcm2837-thermal"
reg: Address range of the thermal registers.
clocks: Phandle of the clock used by the thermal sensor.
-#thermal-sensor-cells: should be 0 (see thermal.txt)
+#thermal-sensor-cells: should be 0 (see Documentation/devicetree/bindings/thermal/thermal-sensor.yaml)

Example:

diff --git a/Documentation/devicetree/bindings/thermal/hisilicon-thermal.txt b/Documentation/devicetree/bindings/thermal/hisilicon-thermal.txt
index cef716a236f1a..4b19d80e6558b 100644
--- a/Documentation/devicetree/bindings/thermal/hisilicon-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/hisilicon-thermal.txt
@@ -9,7 +9,7 @@
by /SOCTHERM/tsensor.
- clock-names: Input clock name, should be 'thermal_clk'.
- clocks: phandles for clock specified in "clock-names" property.
-- #thermal-sensor-cells: Should be 1. See ./thermal.txt for a description.
+- #thermal-sensor-cells: Should be 1. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for a description.

Example :

diff --git a/Documentation/devicetree/bindings/thermal/max77620_thermal.txt b/Documentation/devicetree/bindings/thermal/max77620_thermal.txt
index 323a3b3822aac..82ed5d4879666 100644
--- a/Documentation/devicetree/bindings/thermal/max77620_thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/max77620_thermal.txt
@@ -8,12 +8,12 @@ below threshold level.

Required properties:
-------------------
-#thermal-sensor-cells: Please refer <devicetree/bindings/thermal/thermal.txt>
- for more details.
+#thermal-sensor-cells: For more details, please refer to
+ <devicetree/bindings/thermal/thermal-sensor.yaml>
The value must be 0.

For more details, please refer generic thermal DT binding document
-<devicetree/bindings/thermal/thermal.txt>.
+<devicetree/bindings/thermal/thermal*.yaml>.

Please refer <devicetree/bindings/mfd/max77620.txt> for mfd DT binding
document for the MAX77620.
diff --git a/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt b/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt
index f8d7831f39740..1e249c42fae04 100644
--- a/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt
@@ -23,7 +23,7 @@ Required properties:
- resets: Reference to the reset controller controlling the thermal controller.
- mediatek,auxadc: A phandle to the AUXADC which the thermal controller uses
- mediatek,apmixedsys: A phandle to the APMIXEDSYS controller.
-- #thermal-sensor-cells : Should be 0. See ./thermal.txt for a description.
+- #thermal-sensor-cells : Should be 0. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for a description.

Optional properties:
- nvmem-cells: A phandle to the calibration data provided by a nvmem device. If
diff --git a/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt b/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt
index f02f38527a6b6..db880e7ed713e 100644
--- a/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt
+++ b/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt
@@ -28,9 +28,10 @@ Required properties :
See ../reset/reset.txt for details.
- reset-names : Must include the following entries:
- soctherm
-- #thermal-sensor-cells : Should be 1. See ./thermal.txt for a description
- of this property. See <dt-bindings/thermal/tegra124-soctherm.h> for a
- list of valid values when referring to thermal sensors.
+- #thermal-sensor-cells : Should be 1. For a description of this property, see
+ Documentation/devicetree/bindings/thermal/thermal-sensor.yaml.
+ See <dt-bindings/thermal/tegra124-soctherm.h> for a list of valid values
+ when referring to thermal sensors.
- throttle-cfgs: A sub-node which is a container of configuration for each
hardware throttle events. These events can be set as cooling devices.
* throttle events: Sub-nodes must be named as "light" or "heavy".
@@ -62,7 +63,8 @@ Required properties :
TEGRA_SOCTHERM_THROT_LEVEL_MED (75%),
TEGRA_SOCTHERM_THROT_LEVEL_HIGH (85%).
- #cooling-cells: Should be 1. This cooling device only support on/off state.
- See ./thermal.txt for a description of this property.
+ For a description of this property see:
+ Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml

Optional properties: The following properties are T210 specific and
valid only for OCx throttle events.
diff --git a/Documentation/devicetree/bindings/thermal/nvidia,tegra186-bpmp-thermal.txt b/Documentation/devicetree/bindings/thermal/nvidia,tegra186-bpmp-thermal.txt
index e17c07be270b7..fc87f6aa1b8f5 100644
--- a/Documentation/devicetree/bindings/thermal/nvidia,tegra186-bpmp-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/nvidia,tegra186-bpmp-thermal.txt
@@ -8,7 +8,7 @@ exposed by BPMP.
The BPMP thermal node must be located directly inside the main BPMP node. See
../firmware/nvidia,tegra186-bpmp.txt for details of the BPMP binding.

-This node represents a thermal sensor. See thermal.txt for details of the
+This node represents a thermal sensor. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for details of the
core thermal binding.

Required properties:
diff --git a/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt b/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt
index 0273a92a2a849..2d5b2ad03314b 100644
--- a/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt
+++ b/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt
@@ -8,7 +8,7 @@ Required properties:
- compatible: Should contain "qcom,spmi-temp-alarm".
- reg: Specifies the SPMI address.
- interrupts: PMIC temperature alarm interrupt.
-- #thermal-sensor-cells: Should be 0. See thermal.txt for a description.
+- #thermal-sensor-cells: Should be 0. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for a description.

Optional properties:
- io-channels: Should contain IIO channel specifier for the ADC channel,
diff --git a/Documentation/devicetree/bindings/thermal/rockchip-thermal.txt b/Documentation/devicetree/bindings/thermal/rockchip-thermal.txt
index c6aac9bcacf1c..7f94669e9ebef 100644
--- a/Documentation/devicetree/bindings/thermal/rockchip-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/rockchip-thermal.txt
@@ -24,7 +24,7 @@ Required properties:
- pinctrl-1 : The "default" pinctrl state, it will be set after reset the
TSADC controller.
- pinctrl-2 : The "sleep" pinctrl state, it will be in for suspend.
-- #thermal-sensor-cells : Should be 1. See ./thermal.txt for a description.
+- #thermal-sensor-cells : Should be 1. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for a description.

Optional properties:
- rockchip,hw-tshut-temp : The hardware-controlled shutdown temperature value.
diff --git a/Documentation/devicetree/bindings/thermal/tango-thermal.txt b/Documentation/devicetree/bindings/thermal/tango-thermal.txt
index 212198d4b9379..2c918d742867a 100644
--- a/Documentation/devicetree/bindings/thermal/tango-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/tango-thermal.txt
@@ -4,7 +4,7 @@ The SMP8758 SoC includes 3 instances of this temperature sensor
(in the CPU, video decoder, and PCIe controller).

Required properties:
-- #thermal-sensor-cells: Should be 0 (see thermal.txt)
+- #thermal-sensor-cells: Should be 0 (see Documentation/devicetree/bindings/thermal/thermal-sensor.yaml)
- compatible: "sigma,smp8758-thermal"
- reg: Address range of the thermal registers

diff --git a/Documentation/devicetree/bindings/thermal/thermal-generic-adc.txt b/Documentation/devicetree/bindings/thermal/thermal-generic-adc.txt
index 691a09db2fefc..e136946a2f4fd 100644
--- a/Documentation/devicetree/bindings/thermal/thermal-generic-adc.txt
+++ b/Documentation/devicetree/bindings/thermal/thermal-generic-adc.txt
@@ -8,7 +8,7 @@ temperature using voltage-temperature lookup table.
Required properties:
===================
- compatible: Must be "generic-adc-thermal".
-- #thermal-sensor-cells: Should be 1. See ./thermal.txt for a description
+- #thermal-sensor-cells: Should be 1. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for a description
of this property.
Optional properties:
===================
diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
deleted file mode 100644
index f78bec19ca358..0000000000000
--- a/Documentation/devicetree/bindings/thermal/thermal.txt
+++ /dev/null
@@ -1,586 +0,0 @@
-* Thermal Framework Device Tree descriptor
-
-This file describes a generic binding to provide a way of
-defining hardware thermal structure using device tree.
-A thermal structure includes thermal zones and their components,
-such as trip points, polling intervals, sensors and cooling devices
-binding descriptors.
-
-The target of device tree thermal descriptors is to describe only
-the hardware thermal aspects. The thermal device tree bindings are
-not about how the system must control or which algorithm or policy
-must be taken in place.
-
-There are five types of nodes involved to describe thermal bindings:
-- thermal sensors: devices which may be used to take temperature
- measurements.
-- cooling devices: devices which may be used to dissipate heat.
-- trip points: describe key temperatures at which cooling is recommended. The
- set of points should be chosen based on hardware limits.
-- cooling maps: used to describe links between trip points and cooling devices;
-- thermal zones: used to describe thermal data within the hardware;
-
-The following is a description of each of these node types.
-
-* Thermal sensor devices
-
-Thermal sensor devices are nodes providing temperature sensing capabilities on
-thermal zones. Typical devices are I2C ADC converters and bandgaps. These are
-nodes providing temperature data to thermal zones. Thermal sensor devices may
-control one or more internal sensors.
-
-Required property:
-- #thermal-sensor-cells: Used to provide sensor device specific information
- Type: unsigned while referring to it. Typically 0 on thermal sensor
- Size: one cell nodes with only one sensor, and at least 1 on nodes
- with several internal sensors, in order
- to identify uniquely the sensor instances within
- the IC. See thermal zone binding for more details
- on how consumers refer to sensor devices.
-
-* Cooling device nodes
-
-Cooling devices are nodes providing control on power dissipation. There
-are essentially two ways to provide control on power dissipation. First
-is by means of regulating device performance, which is known as passive
-cooling. A typical passive cooling is a CPU that has dynamic voltage and
-frequency scaling (DVFS), and uses lower frequencies as cooling states.
-Second is by means of activating devices in order to remove
-the dissipated heat, which is known as active cooling, e.g. regulating
-fan speeds. In both cases, cooling devices shall have a way to determine
-the state of cooling in which the device is.
-
-Any cooling device has a range of cooling states (i.e. different levels
-of heat dissipation). For example a fan's cooling states correspond to
-the different fan speeds possible. Cooling states are referred to by
-single unsigned integers, where larger numbers mean greater heat
-dissipation. The precise set of cooling states associated with a device
-should be defined in a particular device's binding.
-For more examples of cooling devices, refer to the example sections below.
-
-Required properties:
-- #cooling-cells: Used to provide cooling device specific information
- Type: unsigned while referring to it. Must be at least 2, in order
- Size: one cell to specify minimum and maximum cooling state used
- in the reference. The first cell is the minimum
- cooling state requested and the second cell is
- the maximum cooling state requested in the reference.
- See Cooling device maps section below for more details
- on how consumers refer to cooling devices.
-
-* Trip points
-
-The trip node is a node to describe a point in the temperature domain
-in which the system takes an action. This node describes just the point,
-not the action.
-
-Required properties:
-- temperature: An integer indicating the trip temperature level,
- Type: signed in millicelsius.
- Size: one cell
-
-- hysteresis: A low hysteresis value on temperature property (above).
- Type: unsigned This is a relative value, in millicelsius.
- Size: one cell
-
-- type: a string containing the trip type. Expected values are:
- "active": A trip point to enable active cooling
- "passive": A trip point to enable passive cooling
- "hot": A trip point to notify emergency
- "critical": Hardware not reliable.
- Type: string
-
-* Cooling device maps
-
-The cooling device maps node is a node to describe how cooling devices
-get assigned to trip points of the zone. The cooling devices are expected
-to be loaded in the target system.
-
-Required properties:
-- cooling-device: A list of phandles of cooling devices with their specifiers,
- Type: phandle + referring to which cooling devices are used in this
- cooling specifier binding. In the cooling specifier, the first cell
- is the minimum cooling state and the second cell
- is the maximum cooling state used in this map.
-- trip: A phandle of a trip point node within the same thermal
- Type: phandle of zone.
- trip point node
-
-Optional property:
-- contribution: The cooling contribution to the thermal zone of the
- Type: unsigned referred cooling device at the referred trip point.
- Size: one cell The contribution is a ratio of the sum
- of all cooling contributions within a thermal zone.
-
-Note: Using the THERMAL_NO_LIMIT (-1UL) constant in the cooling-device phandle
-limit specifier means:
-(i) - minimum state allowed for minimum cooling state used in the reference.
-(ii) - maximum state allowed for maximum cooling state used in the reference.
-Refer to include/dt-bindings/thermal/thermal.h for definition of this constant.
-
-* Thermal zone nodes
-
-The thermal zone node is the node containing all the required info
-for describing a thermal zone, including its cooling device bindings. The
-thermal zone node must contain, apart from its own properties, one sub-node
-containing trip nodes and one sub-node containing all the zone cooling maps.
-
-Required properties:
-- polling-delay: The maximum number of milliseconds to wait between polls
- Type: unsigned when checking this thermal zone.
- Size: one cell
-
-- polling-delay-passive: The maximum number of milliseconds to wait
- Type: unsigned between polls when performing passive cooling.
- Size: one cell
-
-- thermal-sensors: A list of thermal sensor phandles and sensor specifier
- Type: list of used while monitoring the thermal zone.
- phandles + sensor
- specifier
-
-- trips: A sub-node which is a container of only trip point nodes
- Type: sub-node required to describe the thermal zone.
-
-Optional property:
-- cooling-maps: A sub-node which is a container of only cooling device
- Type: sub-node map nodes, used to describe the relation between trips
- and cooling devices.
-
-- coefficients: An array of integers (one signed cell) containing
- Type: array coefficients to compose a linear relation between
- Elem size: one cell the sensors listed in the thermal-sensors property.
- Elem type: signed Coefficients defaults to 1, in case this property
- is not specified. A simple linear polynomial is used:
- Z = c0 * x0 + c1 * x1 + ... + c(n-1) * x(n-1) + cn.
-
- The coefficients are ordered and they match with sensors
- by means of sensor ID. Additional coefficients are
- interpreted as constant offset.
-
-- sustainable-power: An estimate of the sustainable power (in mW) that the
- Type: unsigned thermal zone can dissipate at the desired
- Size: one cell control temperature. For reference, the
- sustainable power of a 4'' phone is typically
- 2000mW, while on a 10'' tablet is around
- 4500mW.
-
-Note: The delay properties are bound to the maximum dT/dt (temperature
-derivative over time) in two situations for a thermal zone:
-(i) - when passive cooling is activated (polling-delay-passive); and
-(ii) - when the zone just needs to be monitored (polling-delay) or
-when active cooling is activated.
-
-The maximum dT/dt is highly bound to hardware power consumption and dissipation
-capability. The delays should be chosen to account for said max dT/dt,
-such that a device does not cross several trip boundaries unexpectedly
-between polls. Choosing the right polling delays shall avoid having the
-device in temperature ranges that may damage the silicon structures and
-reduce silicon lifetime.
-
-* The thermal-zones node
-
-The "thermal-zones" node is a container for all thermal zone nodes. It shall
-contain only sub-nodes describing thermal zones as in the section
-"Thermal zone nodes". The "thermal-zones" node appears under "/".
-
-* Examples
-
-Below are several examples on how to use thermal data descriptors
-using device tree bindings:
-
-(a) - CPU thermal zone
-
-The CPU thermal zone example below describes how to setup one thermal zone
-using one single sensor as temperature source and many cooling devices and
-power dissipation control sources.
-
-#include <dt-bindings/thermal/thermal.h>
-
-cpus {
- /*
- * Here is an example of describing a cooling device for a DVFS
- * capable CPU. The CPU node describes its four OPPs.
- * The cooling states possible are 0..3, and they are
- * used as OPP indexes. The minimum cooling state is 0, which means
- * all four OPPs can be available to the system. The maximum
- * cooling state is 3, which means only the lowest OPPs (198MHz@0.85V)
- * can be available in the system.
- */
- cpu0: cpu@0 {
- ...
- operating-points = <
- /* kHz uV */
- 970000 1200000
- 792000 1100000
- 396000 950000
- 198000 850000
- >;
- #cooling-cells = <2>; /* min followed by max */
- };
- ...
-};
-
-&i2c1 {
- ...
- /*
- * A simple fan controller which supports 10 speeds of operation
- * (represented as 0-9).
- */
- fan0: fan@48 {
- ...
- #cooling-cells = <2>; /* min followed by max */
- };
-};
-
-ocp {
- ...
- /*
- * A simple IC with a single bandgap temperature sensor.
- */
- bandgap0: bandgap@0000ed00 {
- ...
- #thermal-sensor-cells = <0>;
- };
-};
-
-thermal-zones {
- cpu_thermal: cpu-thermal {
- polling-delay-passive = <250>; /* milliseconds */
- polling-delay = <1000>; /* milliseconds */
-
- thermal-sensors = <&bandgap0>;
-
- trips {
- cpu_alert0: cpu-alert0 {
- temperature = <90000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "active";
- };
- cpu_alert1: cpu-alert1 {
- temperature = <100000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "passive";
- };
- cpu_crit: cpu-crit {
- temperature = <125000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "critical";
- };
- };
-
- cooling-maps {
- map0 {
- trip = <&cpu_alert0>;
- cooling-device = <&fan0 THERMAL_NO_LIMIT 4>;
- };
- map1 {
- trip = <&cpu_alert1>;
- cooling-device = <&fan0 5 THERMAL_NO_LIMIT>, <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
- };
- };
- };
-};
-
-In the example above, the ADC sensor (bandgap0) at address 0x0000ED00 is
-used to monitor the zone 'cpu-thermal' using its sole sensor. A fan
-device (fan0) is controlled via I2C bus 1, at address 0x48, and has ten
-different cooling states 0-9. It is used to remove the heat out of
-the thermal zone 'cpu-thermal' using its cooling states
-from its minimum to 4, when it reaches trip point 'cpu_alert0'
-at 90C, as an example of active cooling. The same cooling device is used at
-'cpu_alert1', but from 5 to its maximum state. The cpu@0 device is also
-linked to the same thermal zone, 'cpu-thermal', as a passive cooling device,
-using all its cooling states at trip point 'cpu_alert1',
-which is a trip point at 100C. On the thermal zone 'cpu-thermal', at the
-temperature of 125C, represented by the trip point 'cpu_crit', the silicon
-is not reliable anymore.
-
-(b) - IC with several internal sensors
-
-The example below describes how to deploy several thermal zones based off a
-single sensor IC, assuming it has several internal sensors. This is a common
-case on SoC designs with several internal IPs that may need different thermal
-requirements, and thus may have their own sensor to monitor or detect internal
-hotspots in their silicon.
-
-#include <dt-bindings/thermal/thermal.h>
-
-ocp {
- ...
- /*
- * A simple IC with several bandgap temperature sensors.
- */
- bandgap0: bandgap@0000ed00 {
- ...
- #thermal-sensor-cells = <1>;
- };
-};
-
-thermal-zones {
- cpu_thermal: cpu-thermal {
- polling-delay-passive = <250>; /* milliseconds */
- polling-delay = <1000>; /* milliseconds */
-
- /* sensor ID */
- thermal-sensors = <&bandgap0 0>;
-
- trips {
- /* each zone within the SoC may have its own trips */
- cpu_alert: cpu-alert {
- temperature = <100000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "passive";
- };
- cpu_crit: cpu-crit {
- temperature = <125000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "critical";
- };
- };
-
- cooling-maps {
- /* each zone within the SoC may have its own cooling */
- ...
- };
- };
-
- gpu_thermal: gpu-thermal {
- polling-delay-passive = <120>; /* milliseconds */
- polling-delay = <1000>; /* milliseconds */
-
- /* sensor ID */
- thermal-sensors = <&bandgap0 1>;
-
- trips {
- /* each zone within the SoC may have its own trips */
- gpu_alert: gpu-alert {
- temperature = <90000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "passive";
- };
- gpu_crit: gpu-crit {
- temperature = <105000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "critical";
- };
- };
-
- cooling-maps {
- /* each zone within the SoC may have its own cooling */
- ...
- };
- };
-
- dsp_thermal: dsp-thermal {
- polling-delay-passive = <50>; /* milliseconds */
- polling-delay = <1000>; /* milliseconds */
-
- /* sensor ID */
- thermal-sensors = <&bandgap0 2>;
-
- trips {
- /* each zone within the SoC may have its own trips */
- dsp_alert: dsp-alert {
- temperature = <90000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "passive";
- };
- dsp_crit: gpu-crit {
- temperature = <135000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "critical";
- };
- };
-
- cooling-maps {
- /* each zone within the SoC may have its own cooling */
- ...
- };
- };
-};
-
-In the example above, there is one bandgap IC which has the capability to
-monitor three sensors. The hardware has been designed so that sensors are
-placed on different places in the DIE to monitor different temperature
-hotspots: one for CPU thermal zone, one for GPU thermal zone and the
-other to monitor a DSP thermal zone.
-
-Thus, there is a need to assign each sensor provided by the bandgap IC
-to different thermal zones. This is achieved by means of using the
-#thermal-sensor-cells property and using the first cell of the sensor
-specifier as sensor ID. In the example, then, <bandgap 0> is used to
-monitor CPU thermal zone, <bandgap 1> is used to monitor GPU thermal
-zone and <bandgap 2> is used to monitor DSP thermal zone. Each zone
-may be uncorrelated, having its own dT/dt requirements, trips
-and cooling maps.
-
-
-(c) - Several sensors within one single thermal zone
-
-The example below illustrates how to use more than one sensor within
-one thermal zone.
-
-#include <dt-bindings/thermal/thermal.h>
-
-&i2c1 {
- ...
- /*
- * A simple IC with a single temperature sensor.
- */
- adc: sensor@49 {
- ...
- #thermal-sensor-cells = <0>;
- };
-};
-
-ocp {
- ...
- /*
- * A simple IC with a single bandgap temperature sensor.
- */
- bandgap0: bandgap@0000ed00 {
- ...
- #thermal-sensor-cells = <0>;
- };
-};
-
-thermal-zones {
- cpu_thermal: cpu-thermal {
- polling-delay-passive = <250>; /* milliseconds */
- polling-delay = <1000>; /* milliseconds */
-
- thermal-sensors = <&bandgap0>, /* cpu */
- <&adc>; /* pcb north */
-
- /* hotspot = 100 * bandgap - 120 * adc + 484 */
- coefficients = <100 -120 484>;
-
- trips {
- ...
- };
-
- cooling-maps {
- ...
- };
- };
-};
-
-In some cases, there is a need to use more than one sensor to extrapolate
-a thermal hotspot in the silicon. The above example illustrates this situation.
-For instance, it may be the case that a sensor external to CPU IP may be placed
-close to CPU hotspot and together with internal CPU sensor, it is used
-to determine the hotspot. Assuming this is the case for the above example,
-the hypothetical extrapolation rule would be:
- hotspot = 100 * bandgap - 120 * adc + 484
-
-In other context, the same idea can be used to add fixed offset. For instance,
-consider the hotspot extrapolation rule below:
- hotspot = 1 * adc + 6000
-
-In the above equation, the hotspot is always 6C higher than what is read
-from the ADC sensor. The binding would be then:
- thermal-sensors = <&adc>;
-
- /* hotspot = 1 * adc + 6000 */
- coefficients = <1 6000>;
-
-(d) - Board thermal
-
-The board thermal example below illustrates how to setup one thermal zone
-with many sensors and many cooling devices.
-
-#include <dt-bindings/thermal/thermal.h>
-
-&i2c1 {
- ...
- /*
- * An IC with several temperature sensor.
- */
- adc_dummy: sensor@50 {
- ...
- #thermal-sensor-cells = <1>; /* sensor internal ID */
- };
-};
-
-thermal-zones {
- batt-thermal {
- polling-delay-passive = <500>; /* milliseconds */
- polling-delay = <2500>; /* milliseconds */
-
- /* sensor ID */
- thermal-sensors = <&adc_dummy 4>;
-
- trips {
- ...
- };
-
- cooling-maps {
- ...
- };
- };
-
- board_thermal: board-thermal {
- polling-delay-passive = <1000>; /* milliseconds */
- polling-delay = <2500>; /* milliseconds */
-
- /* sensor ID */
- thermal-sensors = <&adc_dummy 0>, /* pcb top edge */
- <&adc_dummy 1>, /* lcd */
- <&adc_dummy 2>; /* back cover */
- /*
- * An array of coefficients describing the sensor
- * linear relation. E.g.:
- * z = c1*x1 + c2*x2 + c3*x3
- */
- coefficients = <1200 -345 890>;
-
- sustainable-power = <2500>;
-
- trips {
- /* Trips are based on resulting linear equation */
- cpu_trip: cpu-trip {
- temperature = <60000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "passive";
- };
- gpu_trip: gpu-trip {
- temperature = <55000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "passive";
- }
- lcd_trip: lcp-trip {
- temperature = <53000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "passive";
- };
- crit_trip: crit-trip {
- temperature = <68000>; /* millicelsius */
- hysteresis = <2000>; /* millicelsius */
- type = "critical";
- };
- };
-
- cooling-maps {
- map0 {
- trip = <&cpu_trip>;
- cooling-device = <&cpu0 0 2>;
- contribution = <55>;
- };
- map1 {
- trip = <&gpu_trip>;
- cooling-device = <&gpu0 0 2>;
- contribution = <20>;
- };
- map2 {
- trip = <&lcd_trip>;
- cooling-device = <&lcd0 5 10>;
- contribution = <15>;
- };
- };
- };
-};
-
-The above example is a mix of previous examples, a sensor IP with several internal
-sensors used to monitor different zones, one of them is composed by several sensors and
-with different cooling devices.
--