From
SubjectRe: [PATCH] i2c: algo-pca: Add 0x78 as SCL stuck low status
Hi Chris,

thanks for the patch!

On Mon, Jun 22, 2020 at 10:57:05AM +1200, Chris Packham wrote:
> The PCA9665 datasheet says that I2CSTA = 78h indicates that SCL is stuck
> low, this differs to the PCA9564 which uses 90h for this indication.
> Treat either 0x78 or 0x90 as an indication that the SCL line is stuck.
>
> Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz>
> ---
> Based on looking through the PCA9564 and PCA9665 datasheets this should be
> safe. The PCA9564 should not return 0x78 for any valid state and the PCA9665
> should not return 0x90.

On the other hand, we know which type was detected, so we could check
for the correct type?

Kind regards,

Wolfram