Messages in this thread |  | | Date | Sun, 14 Jun 2020 00:40:14 +0200 | From | Andrea Mayer <> | Subject | Re: [RFC,net-next, 3/5] vrf: add sysctl parameter for strict mode |
| |
On Fri, 12 Jun 2020 10:52:27 -0700 Jakub Kicinski <kuba@kernel.org> wrote:
> drivers/net/vrf.c:1771:49: warning: incorrect type in argument 3 (different address spaces) > drivers/net/vrf.c:1771:49: expected void * > drivers/net/vrf.c:1771:49: got void [noderef] <asn:1> *buffer > drivers/net/vrf.c:1785:35: warning: incorrect type in initializer (incompatible argument 3 (different address spaces)) > drivers/net/vrf.c:1785:35: expected int ( [usertype] *proc_handler )( ... ) > drivers/net/vrf.c:1785:35: got int ( * )( ... )
Hi Jakub, the fix will be in the next version of this patch set.
Thank you, Andrea
|  |