Messages in this thread | | | Date | Thu, 11 Jun 2020 15:29:09 +0200 | From | Andrew Lunn <> | Subject | Re: [PATCH v2 2/2] net: phy: mscc: handle the clkout control on some phy variants |
| |
On Tue, Jun 09, 2020 at 03:31:40PM +0200, Heiko Stuebner wrote: > From: Heiko Stuebner <heiko.stuebner@theobroma-systems.com> > > At least VSC8530/8531/8540/8541 contain a clock output that can emit > a predefined rate of 25, 50 or 125MHz. > > This may then feed back into the network interface as source clock. > So follow the example the at803x already set and introduce a > vsc8531,clk-out-frequency property to set that output. > > Signed-off-by: Heiko Stuebner <heiko.stuebner@theobroma-systems.com> > --- > Hi Andrew, > > I didn't change the property yet, do you have a suggestion on > how to name it though? Going by the other examples in the > ethernet-phy.yamls, something like enet-phy-clock-out-frequency ?
Hi Heiko
Yes, that looks good.
Thanks Andrew
| |