lkml.org 
[lkml]   [2020]   [May]   [4]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
Date
From
Subject[PATCH v3 2/8] power: bq25890: fix ADC mode configuration
Datasheet describes two modes for reading ADC measurements:
1. continuous, 1 Hz - enabled and started by CONV_RATE bit
2. one-shot - triggered by CONV_START bit

In continuous mode, CONV_START is read-only and signifies an ongoing
conversion.

Change the code to follow the datasheet and really disable continuous
mode for power saving.

Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
---
v3: drop dependency on new input/output properties
---
drivers/power/supply/bq25890_charger.c | 31 +++++++++++++++++++++-----
1 file changed, 26 insertions(+), 5 deletions(-)

diff --git a/drivers/power/supply/bq25890_charger.c b/drivers/power/supply/bq25890_charger.c
index 70ecc38fe772..325fdd1b1d23 100644
--- a/drivers/power/supply/bq25890_charger.c
+++ b/drivers/power/supply/bq25890_charger.c
@@ -126,6 +126,7 @@ static const struct regmap_access_table bq25890_writeable_regs = {

static const struct regmap_range bq25890_volatile_reg_ranges[] = {
regmap_reg_range(0x00, 0x00),
+ regmap_reg_range(0x02, 0x02),
regmap_reg_range(0x09, 0x09),
regmap_reg_range(0x0b, 0x14),
};
@@ -374,18 +375,38 @@ enum bq25890_chrg_fault {
CHRG_FAULT_TIMER_EXPIRED,
};

+static bool bq25890_is_adc_property(enum power_supply_property psp)
+{
+ switch (psp) {
+ case POWER_SUPPLY_PROP_VOLTAGE_NOW:
+ case POWER_SUPPLY_PROP_CURRENT_NOW:
+ return true;
+
+ default:
+ return false;
+ }
+}
+
static int bq25890_power_supply_get_property(struct power_supply *psy,
enum power_supply_property psp,
union power_supply_propval *val)
{
- int ret;
struct bq25890_device *bq = power_supply_get_drvdata(psy);
struct bq25890_state state;
+ bool do_adc_conv;
+ int ret;

mutex_lock(&bq->lock);
state = bq->state;
+ do_adc_conv = !state.online && bq25890_is_adc_property(psp);
+ if (do_adc_conv)
+ bq25890_field_write(bq, F_CONV_START, 1);
mutex_unlock(&bq->lock);

+ if (do_adc_conv)
+ regmap_field_read_poll_timeout(bq->rmap_fields[F_CONV_START],
+ ret, !ret, 25000, 1000000);
+
switch (psp) {
case POWER_SUPPLY_PROP_STATUS:
if (!state.online)
@@ -623,8 +644,8 @@ static int bq25890_hw_init(struct bq25890_device *bq)
}
}

- /* Configure ADC for continuous conversions. This does not enable it. */
- ret = bq25890_field_write(bq, F_CONV_RATE, 1);
+ /* Configure ADC for continuous conversions when charging */
+ ret = bq25890_field_write(bq, F_CONV_RATE, !!bq->state.online);
if (ret < 0) {
dev_dbg(bq->dev, "Config ADC failed %d\n", ret);
return ret;
@@ -966,7 +987,7 @@ static int bq25890_suspend(struct device *dev)
* If charger is removed, while in suspend, make sure ADC is diabled
* since it consumes slightly more power.
*/
- return bq25890_field_write(bq, F_CONV_START, 0);
+ return bq25890_field_write(bq, F_CONV_RATE, 0);
}

static int bq25890_resume(struct device *dev)
@@ -982,7 +1003,7 @@ static int bq25890_resume(struct device *dev)

/* Re-enable ADC only if charger is plugged in. */
if (bq->state.online) {
- ret = bq25890_field_write(bq, F_CONV_START, 1);
+ ret = bq25890_field_write(bq, F_CONV_RATE, 1);
if (ret < 0)
return ret;
}
--
2.20.1
\
 
 \ /
  Last update: 2020-05-04 21:48    [W:0.063 / U:0.168 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site