SubjectRe: [PATCH net-next v3 1/2] ethtool: provide UAPI for PHY Signal Quality Index (SQI)
On Wed, May 20, 2020 at 08:29:14AM +0200, Oleksij Rempel wrote:
> Signal Quality Index is a mandatory value required by "OPEN Alliance
> SIG" for the 100Base-T1 PHYs [1]. This indicator can be used for cable
> integrity diagnostic and investigating other noise sources and
> implement by at least two vendors: NXP[2] and TI[3].
>
> [1] http://www.opensig.org/download/document/218/Advanced_PHY_features_for_automotive_Ethernet_V1.0.pdf
> [2] https://www.nxp.com/docs/en/data-sheet/TJA1100.pdf
> [3] https://www.ti.com/product/DP83TC811R-Q1
>
> Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>

Reviewed-by: Andrew Lunn <andrew@lunn.ch>

Andrew

\
 
 \ /