Messages in this thread | | | Date | Tue, 21 Apr 2020 11:02:20 -0700 | From | Tony Lindgren <> | Subject | Re: [PATCHv3] w1: omap-hdq: Simplify driver with PM runtime autosuspend |
| |
* Andreas Kemnade <andreas@kemnade.info> [200421 06:54]: > On Mon, 20 Apr 2020 23:11:18 +0200 > "H. Nikolaus Schaller" <hns@goldelico.com> wrote: > > The only maybe important observation was when I disabled all > > kernel modules except *hdq*.ko and *bq27*.ko. Then I did only > > get an emergency shell so that it is quite similar to the > > scenario Andreas has tested. With this setup it did work. > > > So I guess without idling uarts? > > > I then tried to reenable other kernel modules but the result > > wasn't convincing that it gives a reliable result. > > > > So I have still no clear indication when the problem occurs and > > when not. > > > Hmm, last summer I had problems even without that patch reading > temperature while doing umts transfers. Maybe there are some > connections, > maybe not. For that scenario we might have emc issues, thermal problems > or a real kernel problem.
I have confimed here that logicpd torpedo devkit with battery works just fine while entering off mode during idle. I can see the temperature just fine with:
# cat /sys/class/power_supply/bq27000-battery/uevent POWER_SUPPLY_NAME=bq27000-battery POWER_SUPPLY_STATUS=Charging POWER_SUPPLY_PRESENT=1 POWER_SUPPLY_VOLTAGE_NOW=3829000 POWER_SUPPLY_CURRENT_NOW=-592084 POWER_SUPPLY_CAPACITY_LEVEL=Normal POWER_SUPPLY_TEMP=306 POWER_SUPPLY_TECHNOLOGY=Li-ion POWER_SUPPLY_CHARGE_FULL_DESIGN=2056320 POWER_SUPPLY_CYCLE_COUNT=0 POWER_SUPPLY_POWER_AVG=0 POWER_SUPPLY_MANUFACTURER=Texas Instruments
This is 37xx though, maybe you have 35xx and there's some errata that we're not handling?
I'm only seeing "2.7. HDQTM/1-Wire® Communication Constraints" for external pull-up resitor in 34xx errata at [0].
I wonder if wrong external pull could cause flakyeness after enabling the hdq module?
If nothing else helps, you could try to block idle for hdq module, but I have a feeling that's a workaround for something else.
Regards,
Tony
[0] https://www.ti.com/pdfs/wtbu/SWPZ009A_OMAP4430_Errata_Public_vA.pdf
| |