Messages in this thread | | | Subject | Re: [PATCH] clk: vc5: Use "idt,voltage-microvolt" instead of "idt,voltage-microvolts" | From | Stephen Boyd <> | Date | Sat, 19 Dec 2020 16:09:30 -0800 |
| |
Quoting Geert Uytterhoeven (2020-12-18 04:52:53) > Commit 45c940184b501fc6 ("dt-bindings: clk: versaclock5: convert to > yaml") accidentally changed "idt,voltage-microvolts" to > "idt,voltage-microvolt" in the DT bindings, while the driver still used > the former. > > Update the driver to match the bindings, as > Documentation/devicetree/bindings/property-units.txt actually recommends > using "microvolt". > > Fixes: 260249f929e81d3d ("clk: vc5: Enable addition output configurations of the Versaclock") > Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> > ---
Applied to clk-next
| |