On Tue, 3 Nov 2020 09:44:35 +0200 Alexandru Ardelean wrote:
> When the PHY powers up, the diagnostics clock isn't enabled (bit 2 in
> register PHY_CTRL_1 (0x0012)).
> Also, the PHY is not in standby mode, so bit 13 in PHY_CTRL_3 (0x0017) is
> always set at power up.
>
> The standby mode and the diagnostics clock are both meant to be for the
> cable diagnostics feature of the PHY (in phylib this would be equivalent to
> the cable-test support), and for the frame-generator feature of the PHY.
>
> In standby mode, the PHY doesn't negotiate links or manage links.
>
> To use the cable diagnostics/test (or frame-generator), the PHY must be
> first set in standby mode, so that the link operation doesn't interfere.
> Then, the diagnostics clock must be enabled.
>
> For the cable-test feature, when the operation finishes, the PHY goes into
> PHY_UP state, and the config_aneg hook is called.
>
> For the ADIN PHY, we need to make sure that during autonegotiation
> configuration/setup the PHY is removed from standby mode and the
> diagnostics clock is disabled, so that normal operation is resumed.
>
> This change does that by moving the set of the ADIN1300_LINKING_EN bit (2)
> in the config_aneg (to disable standby mode).
> Previously, this was set in the downshift setup, because the downshift
> retry value and the ADIN1300_LINKING_EN are in the same register.
>
> And the ADIN1300_DIAG_CLK_EN bit (13) is cleared, to disable the
> diagnostics clock.
>
> Reviewed-by: Andrew Lunn <andrew@lunn.ch>
> Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com>

Applied both, thanks.

\
 
 \ /
  Last update: 2020-11-05 02:07    [W:0.039 / U:0.452 seconds]