Messages in this thread |  | | Subject | Re: [PATCH] usb: dwc3: meson-g12a: disable clk on error handling path in probe | From | Zheng Zengkai <> | Date | Fri, 27 Nov 2020 15:31:11 +0800 |
| |
Ping...
> On Wed, Nov 11, 2020 at 10:48 AM Zheng Zengkai <zhengzengkai@huawei.com> wrote: >> dwc3_meson_g12a_probe() does not invoke clk_bulk_disable_unprepare() >> on one error handling path. This patch fixes that. >> >> Fixes: 347052e3bf1b ("usb: dwc3: meson-g12a: fix USB2 PHY initialization on G12A and A1 SoCs") >> Reported-by: Hulk Robot <hulkci@huawei.com> >> Signed-off-by: Zheng Zengkai <zhengzengkai@huawei.com> > Reviewed-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com> > > many thanks for this fix! > > > Best regards > Martin > . >
|  |