lkml.org 
[lkml]   [2020]   [Oct]   [27]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
    Patch in this message
    /
    From
    Subject[PATCH 5.9 179/757] hwmon: (bt1-pvt) Wait for the completion with timeout
    Date
    From: Serge Semin <Sergey.Semin@baikalelectronics.ru>

    [ Upstream commit 0ffd21d5985506d164ada9e8fff6daae8ef469a1 ]

    If the PVT sensor is suddenly powered down while a caller is waiting for
    the conversion completion, the request won't be finished and the task will
    hang up on this procedure until the power is back up again. Let's call the
    wait_for_completion_timeout() method instead to prevent that. The cached
    timeout is exactly what we need to predict for how long conversion could
    normally last.

    Fixes: 87976ce2825d ("hwmon: Add Baikal-T1 PVT sensor driver")
    Signed-off-by: Serge Semin <Sergey.Semin@baikalelectronics.ru>
    Link: https://lore.kernel.org/r/20200920110924.19741-4-Sergey.Semin@baikalelectronics.ru
    Signed-off-by: Guenter Roeck <linux@roeck-us.net>
    Signed-off-by: Sasha Levin <sashal@kernel.org>
    ---
    drivers/hwmon/bt1-pvt.c | 13 ++++++++++++-
    1 file changed, 12 insertions(+), 1 deletion(-)

    diff --git a/drivers/hwmon/bt1-pvt.c b/drivers/hwmon/bt1-pvt.c
    index 2600426a3b21c..3e1d56585b91a 100644
    --- a/drivers/hwmon/bt1-pvt.c
    +++ b/drivers/hwmon/bt1-pvt.c
    @@ -477,6 +477,7 @@ static int pvt_read_data(struct pvt_hwmon *pvt, enum pvt_sensor_type type,
    long *val)
    {
    struct pvt_cache *cache = &pvt->cache[type];
    + unsigned long timeout;
    u32 data;
    int ret;

    @@ -500,7 +501,14 @@ static int pvt_read_data(struct pvt_hwmon *pvt, enum pvt_sensor_type type,
    pvt_update(pvt->regs + PVT_INTR_MASK, PVT_INTR_DVALID, 0);
    pvt_update(pvt->regs + PVT_CTRL, PVT_CTRL_EN, PVT_CTRL_EN);

    - wait_for_completion(&cache->conversion);
    + /*
    + * Wait with timeout since in case if the sensor is suddenly powered
    + * down the request won't be completed and the caller will hang up on
    + * this procedure until the power is back up again. Multiply the
    + * timeout by the factor of two to prevent a false timeout.
    + */
    + timeout = 2 * usecs_to_jiffies(ktime_to_us(pvt->timeout));
    + ret = wait_for_completion_timeout(&cache->conversion, timeout);

    pvt_update(pvt->regs + PVT_CTRL, PVT_CTRL_EN, 0);
    pvt_update(pvt->regs + PVT_INTR_MASK, PVT_INTR_DVALID,
    @@ -510,6 +518,9 @@ static int pvt_read_data(struct pvt_hwmon *pvt, enum pvt_sensor_type type,

    mutex_unlock(&pvt->iface_mtx);

    + if (!ret)
    + return -ETIMEDOUT;
    +
    if (type == PVT_TEMP)
    *val = pvt_calc_poly(&poly_N_to_temp, data);
    else
    --
    2.25.1


    \
     
     \ /