Messages in this thread Patch in this message | | | From | Cristian Marussi <> | Subject | [PATCH v2 3/6] hwmon: scmi: update hwmon internal scale data type | Date | Mon, 26 Oct 2020 20:10:04 +0000 |
| |
Use an int to calculate scale values inside scmi_hwmon_scale() to match the updated scale data type in struct scmi_sensor_info.
Signed-off-by: Cristian Marussi <cristian.marussi@arm.com> --- drivers/hwmon/scmi-hwmon.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/hwmon/scmi-hwmon.c b/drivers/hwmon/scmi-hwmon.c index d421e691318b..e190abc5749a 100644 --- a/drivers/hwmon/scmi-hwmon.c +++ b/drivers/hwmon/scmi-hwmon.c @@ -30,7 +30,7 @@ static inline u64 __pow10(u8 x) static int scmi_hwmon_scale(const struct scmi_sensor_info *sensor, u64 *value) { - s8 scale = sensor->scale; + int scale = sensor->scale; u64 f; switch (sensor->type) { -- 2.17.1
| |