Messages in this thread | | | From | Vladimir Oltean <> | Subject | Re: [PATCH v1 net-next 2/5] net: mscc: ocelot: set vcap IS2 chain to goto PSFP chain | Date | Tue, 20 Oct 2020 23:27:14 +0000 |
| |
On Tue, Oct 20, 2020 at 03:23:18PM +0800, Xiaoliang Yang wrote: > VSC9959 supports Per-Stream Filtering and Policing(PSFP), which is > processing after VCAP blocks. We set this block on chain 30000 and > set vcap IS2 chain to goto PSFP chain if hardware support. > > An example set is: > > tc filter add dev swp0 ingress chain 21000 flower > skip_sw action goto chain 30000 > > Signed-off-by: Xiaoliang Yang <xiaoliang.yang_1@nxp.com> > ---
I will defer to Microchip people whether 30000 is a good chain number for TSN offloads. Do you have other ingress VCAPs that you would like to number 30000?
| |