Messages in this thread | | | Date | Tue, 20 Oct 2020 15:49:40 +0200 | From | Marek Behun <> | Subject | Re: [PATCH v3 1/3] net: dsa: mv88e6xxx: Don't force link when using in-band-status |
| |
On Tue, 20 Oct 2020 11:15:52 +0100 Russell King - ARM Linux admin <linux@armlinux.org.uk> wrote:
> On Tue, Oct 20, 2020 at 04:45:56PM +1300, Chris Packham wrote: > > When a port is configured with 'managed = "in-band-status"' don't force > > the link up, the switch MAC will detect the link status correctly. > > > > Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz> > > Reviewed-by: Andrew Lunn <andrew@lunn.ch> > > I thought we had issues with the 88E6390 where the PCS does not > update the MAC with its results. Isn't this going to break the > 6390? Andrew? >
Russell, I tested this patch on Turris MOX with 6390 on port 9 (cpu port) which is configured in devicetree as 2500base-x, in-band-status, and it works...