Messages in this thread | | | Date | Tue, 7 Jan 2020 12:11:29 +0530 | From | Viresh Kumar <> | Subject | Re: [PATCH 2/2] opp: quiet down WARN when no valid OPPs remain |
| |
On 03-01-20, 20:36, Michał Mirosław wrote: > Per CPU screenful of backtraces is not really that useful. Replace > WARN with a diagnostic discriminating common causes of empty OPP table.
But why should a platform have an OPP table in DT where none of them works for it ? I added the warn intentionally here just for that case.