Messages in this thread | | | Subject | Re: [PATCH 5/5] leds: lm3692x: Use flags from LM3692X_BRT_CTRL | From | Dan Murphy <> | Date | Wed, 18 Sep 2019 13:48:06 -0500 |
| |
Guido
On 9/17/19 9:19 PM, Guido Günther wrote: > Use LM3692X_RAMP_EN instead of LM3692X_PWM_HYSTER_4LSB > since the later is a flag for the PWM register. The > actual register value remains unchanged. > > Signed-off-by: Guido Günther <agx@sigxcpu.org> Reviewed-by: Dan Murphy <dmurphy@ti.com> > --- > drivers/leds/leds-lm3692x.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/leds/leds-lm3692x.c b/drivers/leds/leds-lm3692x.c > index d673f706385e..ecac586ca89c 100644 > --- a/drivers/leds/leds-lm3692x.c > +++ b/drivers/leds/leds-lm3692x.c > @@ -269,7 +269,7 @@ static int lm3692x_init(struct lm3692x_led *led) > goto out; > > ret = regmap_write(led->regmap, LM3692X_BRT_CTRL, > - LM3692X_BL_ADJ_POL | LM3692X_PWM_HYSTER_4LSB); > + LM3692X_BL_ADJ_POL | LM3692X_RAMP_EN); > if (ret) > goto out; >
| |