Messages in this thread | | | Date | Tue, 23 Jul 2019 11:54:32 +0100 | From | Mark Brown <> | Subject | Re: [PATCH] regulator: act8865: support regulator-pull-down property |
| |
On Mon, Jul 22, 2019 at 08:13:29PM +0200, Michał Mirosław wrote: > AC8865 has internal 1.5k pull-down resistor that can be enabled when LDO > is shut down.
This changelog...
> static const struct regulator_ops act8865_ldo_ops = { > + .list_voltage = regulator_list_voltage_linear_range, > + .map_voltage = regulator_map_voltage_linear_range, > + .get_voltage_sel = regulator_get_voltage_sel_regmap, > + .set_voltage_sel = regulator_set_voltage_sel_regmap,
...doesn't obviously match this code change which looks to be implementing voltage setting (as well as the pull down stuff but still). [unhandled content-type:application/pgp-signature] | |