Messages in this thread | | | Date | Mon, 17 Jun 2019 12:40:48 +0100 | From | Mark Brown <> | Subject | Re: [PATCH] regulator: twl: mark vdd1/2 as continuous on twl4030 |
| |
On Mon, Jun 17, 2019 at 01:03:57PM +0200, Andreas Kemnade wrote: > Mark Brown <broonie@kernel.org> wrote: > > On Sat, Jun 15, 2019 at 06:33:14PM +0200, Andreas Kemnade wrote:
> > Why is this a good fix and not defining the supported voltages? These > > look like fairly standard linear range regulators.
> I am fixing the definition of the two regulators in the patch. > I am defining them as continuous. > Voltage ranges are defined in > arch/arm/boot/dts/twl4030.dtsi > Only the continuous flag is missing.
> Is there anything else do you want to be defined?
These regulators are not continuous regulators as far as I can see, they are normal linear range regulators and so should have their voltages enumerable like any other linear range regulator. [unhandled content-type:application/pgp-signature] | |