Messages in this thread | | | Date | Wed, 8 May 2019 12:35:19 +0100 | From | Sudeep Holla <> | Subject | Re: [PATCH v3 0/2] hwmon: scmi: Scale values to target desired HWMON units |
| |
On Tue, May 07, 2019 at 04:09:15PM -0700, Florian Fainelli wrote: > Hi Sudeep, Guenter, > > This patch series adds support for scaling SCMI sensor values read from > firmware. Sudeep, let me know if you think we should be treating scale > == 0 as a special value to preserve some firmware compatibility (not > that this would be desired).
So are we providing raw values from sensors.c and handling conversion in hwmon layer ? I was thinking of just providing converted values to hwmon just in case if the scaling thing change in future with newer versions of SCMI. I am fine either way, just trying to keep hwmon-scmi simpler. I will check if scale = 0 needs to be treated as special(I don't think so, but will read the spec)