Messages in this thread | | | Date | Fri, 26 Apr 2019 18:47:25 +0200 | From | Andrew Lunn <> | Subject | Re: [PATCH net-next] net: phy: micrel: make sure the factory test bit is cleared |
| |
On Fri, Apr 26, 2019 at 06:41:23PM +0200, Antoine Tenart wrote: > The KSZ8081 PHY has a factory test mode which is set at the de-assertion > of the reset line based on the RXER (KSZ8081RNA/RND) or TXC > (KSZ8081MNX/RNB) pin. If a pull-down is missing, or if the pin has a > pull-up, the factory test mode should be cleared by manually writing a 0 > (according to the datasheet). This patch makes sure this factory test > bit is cleared in config_init(). > > Tested-by: Alexandre Belloni <alexandre.belloni@bootlin.com> > Signed-off-by: Antoine Tenart <antoine.tenart@bootlin.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>