lkml.org 
[lkml]   [2019]   [Apr]   [26]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH net-next] net: phy: micrel: make sure the factory test bit is cleared
On Fri, Apr 26, 2019 at 06:41:23PM +0200, Antoine Tenart wrote:
> The KSZ8081 PHY has a factory test mode which is set at the de-assertion
> of the reset line based on the RXER (KSZ8081RNA/RND) or TXC
> (KSZ8081MNX/RNB) pin. If a pull-down is missing, or if the pin has a
> pull-up, the factory test mode should be cleared by manually writing a 0
> (according to the datasheet). This patch makes sure this factory test
> bit is cleared in config_init().
>
> Tested-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
> Signed-off-by: Antoine Tenart <antoine.tenart@bootlin.com>

Reviewed-by: Andrew Lunn <andrew@lunn.ch>

Andrew

\
 
 \ /
  Last update: 2019-04-26 18:48    [W:0.044 / U:0.432 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site