Messages in this thread | | | Subject | Re: [PATCH 3/3] iio: Add PAT9125 optical tracker sensor | From | Alexandre <> | Date | Tue, 23 Apr 2019 10:57:40 +0200 |
| |
Hi Jonathan,
On 4/22/19 10:42, Jonathan Cameron wrote: > On Tue, 16 Apr 2019 14:49:19 +0200 > Alexandre <amergnat@baylibre.com> wrote: > >> Hello Jonathan, >> >> On 4/7/19 12:20, Jonathan Cameron wrote: >>> Hi Alexandre, >>> >>> So I have no problem with this as an IIO driver, but for devices that >>> are somewhat 'on the edge' I always like to get a clear answer to the >>> question: Why not input? >>> >>> I would also argue that, to actually be 'useful' we would typically need >>> some representation of the 'mechanicals' that are providing the motion >>> being measured. Looking at the datasheet this includes, rotating shafts >>> (side or end on), disk edges and flat surface tracking (mouse like). >>> >>> That's easy enough to do with the iio in kernel consumer interface. These >>> are similar to when we handle analog electronic front ends. >>> >>> I you can, please describe what it is being used for in your application >>> as that may give us somewhere to start! >>> >>> + CC Dmitry and linux-input. >> I developed this driver to detect the board movement which can't be >> detected by accelerometer (very slow motion). I admit this use case can >> be handled by an input, and I'm agree with you, PAT9125 driver could be >> an input. But, like you said, this chip is able to track different kind >> of motion, and additionally have an interrupt GPIO, so using it like >> input limit the driver potential. This chip is designed to work in >> industrial measurement or embedded systems, and the IIO API match with >> these environments, so it's the best way to exploit the entire potential >> of this chip. >> >> As I understand (from >> https://www.kernel.org/doc/html/v4.12/input/event-codes.html#mice ), >> mouse driver must report values when the device move. This feature >> souldn't be mandatory for an optical tracker driver, specially for cases >> where user prefers to use buffer or poll only when he need data. >> >>> If 1 or 2, I would suggest that you provide absolute position to >>> Linux. So add the value to a software counter and provide that. >>> 32 bits should be plenty of resolution for that. >> I can't provide absolute position, only relative. Do you mean using >> input driver to do that ? If not, how is built the position data? > Sorry, I should have been clearer on this. > I mean absolute relative to the start point. So on startup you assume > absolute position is 0 and go from there. What I can't work out is > if the device does internal tracking, or whether each time you read > it effectively resets it's internal counters to 0 so the next measurement > is relative to the previous one. Each time you read that reset internal counters to 0. >>> Silly question for you. What happens if you set the delta values to 0? >>> Do we get an interrupt which is effectively data ready? >>> If we do, you might want to think about a scheme where that is an option. >>> As things currently stand we have a confusing interface where changing this >>> threshold effects the buffered data output. That should only be the >>> case if this interface is for a trigger, not an event. >> I'm not sure to understand your question. Is it possible to read delta_x >> and delta_y = 0 in special/corner case because internal value continue >> to be updated after toggled motion_detect pin (used for IRQ) until >> values registers are read and then motion_detect pin is released: >> >> * Chip move (i.e. +2 on X axis and 0 on Y axis) >> * Motion_detect IRQ trigger and internal reg value is updated (i.e. >> delta_x = 2 and delta_y = 0. >> * GPIO IRQ handled but read_value isn't executed yet (timing reason) >> * Chip move back to it origin point (i.e. -2 on X axis and 0 on Y axis) >> * Motion_detect IRQ still low because it hasn't been reset by read >> value and internal reg value is updated (i.e. delta_x = 0 and >> delta_y = 0) >> * Read_value is executed, we get delta values = 0. > Again, I was unclear. Is it possible to set the device to interrupt > every time it evaluates whether motion has occured? Not only when it > concludes that there has been some motion. That would allow the interrupt > to be used as a signal that the device has taken a measurement (data > ready signal in other sensors). > I don't know, the datasheet don't describe the role of each bit in registers and I don't found documentation which provide that. I had to do research on example code to retrieve some bits, but got nothing on motion detection pin configuration.
>>> If it is actually not possible to report the two channels separately >>> then don't report them at all except via the buffered interface and >>> set the available scan masks so that both are on. >> I found a way to keep the consistency between delta x and delta y >> (without losing data). The first part is to reset a value only when user >> read it (also when it's buffered). The second part is to add the new >> value to the old value. With these two mechanism, X and Y will always be >> consistent: >> >> * as possible during a move. >> * perfectly when move is finished. > Ah. This adding old value to a new value point is what I was getting > at (I think) with 'absolute' position above. > > In industrial control for example you have absolute position by using > limit switches to set your baseline. Measurement devices are then > capable of either reporting relative position, which is the movement > since the last reading was taken, or 'absolute' position which is > referenced to some known point. It was this form of absolute position > that I was suggesting you use. If you use such a system without a > limit switch it is normally called unreference motion. You can do > it but then the 0 is where ever your device was at power on. > For some systems it doesn't actually matter (conveyor belts for > instance where the positions you care about are between things > on the belt, not the position of the belt itself).
Ok, I decided to return delta between last read/buffering to stay closer to the hardware mechanism and still coherent with "IIO_CHAN_INFO_RAW". If user want absolute position, he can make an addition of all received value in user space, and that allow him to reset/replace the initial position when he want it.
> Thanks, > > Jonathan > >> >> Regards, >> >> Alexandre >>
Thanks for your comments,