lkml.org 
[lkml]   [2019]   [Mar]   [26]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH 4.19 45/45] power: supply: charger-manager: Fix incorrect return value
Date
4.19-stable review patch.  If anyone has any objections, please let me know.

------------------

From: Baolin Wang <baolin.wang@linaro.org>

commit f25a646fbe2051527ad9721853e892d13a99199e upstream.

Fix incorrect return value.

Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>

---
drivers/power/supply/charger-manager.c | 3 +--
1 file changed, 1 insertion(+), 2 deletions(-)

--- a/drivers/power/supply/charger-manager.c
+++ b/drivers/power/supply/charger-manager.c
@@ -1212,7 +1212,6 @@ static int charger_extcon_init(struct ch
if (ret < 0) {
pr_info("Cannot register extcon_dev for %s(cable: %s)\n",
cable->extcon_name, cable->name);
- ret = -EINVAL;
}

return ret;
@@ -1633,7 +1632,7 @@ static int charger_manager_probe(struct

if (IS_ERR(desc)) {
dev_err(&pdev->dev, "No platform data (desc) found\n");
- return -ENODEV;
+ return PTR_ERR(desc);
}

cm = devm_kzalloc(&pdev->dev, sizeof(*cm), GFP_KERNEL);

\
 
 \ /
  Last update: 2019-03-26 07:44    [W:0.300 / U:0.052 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site