    On Thu, 2019-03-21 at 16:13 +0000, Stefan Hajnoczi wrote:
    > On Tue, Mar 19, 2019 at 04:41:07PM +0200, Maxim Levitsky wrote:
    > > Date: Tue, 19 Mar 2019 14:45:45 +0200
    > > Subject: [PATCH 0/9] RFC: NVME VFIO mediated device
    > >
    > > Hi everyone!
    > >
    > > In this patch series, I would like to introduce my take on the problem of
    > > doing
    > > as fast as possible virtualization of storage with emphasis on low latency.
    > >
    > > In this patch series I implemented a kernel vfio based, mediated device
    > > that
    > > allows the user to pass through a partition and/or whole namespace to a
    > > guest.
    > >
    > > The idea behind this driver is based on paper you can find at
    > > https://www.usenix.org/conference/atc18/presentation/peng,
    > >
    > > Although note that I stared the development prior to reading this paper,
    > > independently.
    > >
    > > In addition to that implementation is not based on code used in the paper
    > > as
    > > I wasn't being able at that time to make the source available to me.
    > >
    > > ***Key points about the implementation:***
    > >
    > > * Polling kernel thread is used. The polling is stopped after a
    > > predefined timeout (1/2 sec by default).
    > > Support for all interrupt driven mode is planned, and it shows promising
    > > results.
    > >
    > > * Guest sees a standard NVME device - this allows to run guest with
    > > unmodified drivers, for example windows guests.
    > >
    > > * The NVMe device is shared between host and guest.
    > > That means that even a single namespace can be split between host
    > > and guest based on different partitions.
    > >
    > > * Simple configuration
    > >
    > > *** Performance ***
    > >
    > > Performance was tested on Intel DC P3700, With Xeon E5-2620 v2
    > > and both latency and throughput is very similar to SPDK.
    > >
    > > Soon I will test this on a better server and nvme device and provide
    > > more formal performance numbers.
    > >
    > > Latency numbers:
    > > ~80ms - spdk with fio plugin on the host.
    > > ~84ms - nvme driver on the host
    > > ~87ms - mdev-nvme + nvme driver in the guest
    >
    > You mentioned the spdk numbers are with vhost-user-nvme. Have you
    > measured SPDK's vhost-user-blk?

    I had lot of measuments of vhost-user-blk vs vhost-user-nvme.
    vhost-user-nvme was always a bit faster but only a bit.
    Thus I don't think it makes sense to benchamrk against vhost-user-blk.

    Best regards,
    Maxim Levitsky



    \
     
     \ /