SubjectRe: [PATCHv2 1/5] Documentation: dt: edac: Fix Stratix10 IRQ bindings
On Wed, Feb 27, 2019 at 11:27:21AM -0600, thor.thayer@linux.intel.com wrote:
> From: Thor Thayer <thor.thayer@linux.intel.com>
>
> Fix Stratix10 ECC bindings to specify only the single
> bit error. On Stratix10 double bit errors are handled
> as SErrors instead of interrupts.
> Indicate the differences between the ARM64 and ARM32
> EDAC architecture in the bindings.
>
> Signed-off-by: Thor Thayer <thor.thayer@linux.intel.com>
> ---
> v2 No change
> ---
> .../devicetree/bindings/edac/socfpga-eccmgr.txt | 23 +++++++++++++++-------
> 1 file changed, 16 insertions(+), 7 deletions(-)
>
> diff --git a/Documentation/devicetree/bindings/edac/socfpga-eccmgr.txt b/Documentation/devicetree/bindings/edac/socfpga-eccmgr.txt
> index 5626560a6cfd..a0ac50e15912 100644
> --- a/Documentation/devicetree/bindings/edac/socfpga-eccmgr.txt
> +++ b/Documentation/devicetree/bindings/edac/socfpga-eccmgr.txt
> @@ -236,33 +236,42 @@ Stratix10 SoCFPGA ECC Manager
> The Stratix10 SoC ECC Manager handles the IRQs for each peripheral
> in a shared register similar to the Arria10. However, ECC requires
> access to registers that can only be read from Secure Monitor with
> -SMC calls. Therefore the device tree is slightly different.
> +SMC calls. Therefore the device tree is slightly different. Note that
> +only 1 interrupt is sent because the double bit errors are treated as
> +SErrors instead of IRQ.
>
> Required Properties:
> - compatible : Should be "altr,socfpga-s10-ecc-manager"
> -- interrupts : Should be single bit error interrupt, then double bit error
> - interrupt.
> +- altr,sysgr-syscon : phandle to Stratix10 System Manager Block
> + containing the ECC manager registers.

Seems this was already in use, but why not just make this node a child
of the System Manager Block and remove this phandle?

> +- interrupts : Should be single bit error interrupt.
> - interrupt-controller : boolean indicator that ECC Manager is an interrupt controller
> - #interrupt-cells : must be set to 2.
> +- #address-cells: must be 1
> +- #size-cells: must be 1
> +- ranges : standard definition, should translate from local addresses
>
> Subcomponents:
>
> SDRAM ECC
> Required Properties:
> - compatible : Should be "altr,sdram-edac-s10"
> -- interrupts : Should be single bit error interrupt, then double bit error
> - interrupt, in this order.
> +- interrupts : Should be single bit error interrupt.
>
> Example:
>
> eccmgr {
> compatible = "altr,socfpga-s10-ecc-manager";
> - interrupts = <0 15 4>, <0 95 4>;
> + altr,sysmgr-syscon = <&sysmgr>;
> + #address-cells = <1>;
> + #size-cells = <1>;
> + interrupts = <0 15 4>;
> interrupt-controller;
> #interrupt-cells = <2>;
> + ranges;
>
> sdramedac {
> compatible = "altr,sdram-edac-s10";
> - interrupts = <16 4>, <48 4>;
> + interrupts = <16 IRQ_TYPE_LEVEL_HIGH>;
> };
> };
> --
> 2.7.4
>

\
 
 \ /