Messages in this thread Patch in this message | | | From | Jerome Brunet <> | Subject | [PATCH v2 3/4] clk: meson: axg-audio does not require syscon | Date | Fri, 1 Feb 2019 13:58:40 +0100 |
| |
The axg audio clock controller uses regmap mmio, not syscon.
Fixes: 1cd50181750f ("clk: meson: axg: add the audio clock controller driver") Signed-off-by: Jerome Brunet <jbrunet@baylibre.com> --- drivers/clk/meson/Kconfig | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/clk/meson/Kconfig b/drivers/clk/meson/Kconfig index efaa70f682b4..2479dab09d70 100644 --- a/drivers/clk/meson/Kconfig +++ b/drivers/clk/meson/Kconfig @@ -50,7 +50,7 @@ config COMMON_CLK_AXG_AUDIO tristate "Meson AXG Audio Clock Controller Driver" depends on COMMON_CLK_AXG select COMMON_CLK_AMLOGIC_AUDIO - select MFD_SYSCON + select REGMAP_MMIO help Support for the audio clock controller on AmLogic A113D devices, aka axg, Say Y if you want audio subsystem to work. -- 2.20.1
| |