Messages in this thread | | | Date | Fri, 28 Sep 2018 17:27:53 -0700 | From | Tony Lindgren <> | Subject | Re: [PATCH] regulator: core: Pass max_uV value to regulator_set_voltage_rdev |
| |
* Dmitry Osipenko <digetx@gmail.com> [180928 23:55]: > On 9/29/18 2:17 AM, Dmitry Osipenko wrote: > > On 9/29/18 1:41 AM, Tony Lindgren wrote: > >> I'm still getting these errors after init: > > > > Thank you very much again, seems I got what's wrong with your case. The ti-abb-regulator driver sets the "abb->current_info_idx = -EINVAL" on probe and that value is getting updated only after the first voltage change, hence _regulator_get_voltage() returns -22.
OK that's starting to make some sense now thanks.
> > Please try this patch: > > I've revised the patch and here is the current final version.
Hey cool this one works now :) I suggest you rework the whole series with these fixes. I recall the series had a problem with git bisect too between the patches. It will make life easier for other people who may need to git bisect these patches.
Thanks,
Tony
| |