Subject[PATCH 4.14 109/173] arm64: dts: uniphier: Add missing cooling device properties for CPUs
Date
4.14-stable review patch.  If anyone has any objections, please let me know.

------------------

From: Viresh Kumar <viresh.kumar@linaro.org>

[ Upstream commit af0e09d0c6762e486b0eb5cc4737396964c34fad ]

The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.

Add such missing properties.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
---
arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi | 2 ++
1 file changed, 2 insertions(+)

--- a/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
+++ b/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
@@ -55,6 +55,7 @@
clocks = <&sys_clk 32>;
enable-method = "psci";
operating-points-v2 = <&cluster0_opp>;
+ #cooling-cells = <2>;
};

cpu2: cpu@100 {
@@ -73,6 +74,7 @@
clocks = <&sys_clk 33>;
enable-method = "psci";
operating-points-v2 = <&cluster1_opp>;
+ #cooling-cells = <2>;
};
};


\
 
 \ /
  Last update: 2018-09-24 14:54    [W:0.554 / U:0.592 seconds]