Messages in this thread | | | Date | Tue, 11 Sep 2018 13:40:29 +0100 | From | Lee Jones <> | Subject | Re: [PATCH 1/8] regulator: bd71837: Disable voltage monitoring for LDO3/4 |
| |
On Wed, 29 Aug 2018, Matti Vaittinen wrote:
> There is a HW quirk in BD71837. The shutdown sequence timings for > bucks/LDOs which are enabled via register interface are changed. > At PMIC poweroff the voltage for BUCK6/7 is cut immediately at the > beginning of shut-down sequence. This causes LDO5/6 voltage > monitoring to detect under voltage and force PMIC to emergency > state instead of poweroff. Disable voltage monitoring for LDO5 and > LDO6 at probe to avoid this. > > Signed-off-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com> > --- > drivers/regulator/bd71837-regulator.c | 19 +++++++++++++++++++
> include/linux/mfd/rohm-bd718x7.h | 33 ++++++++++++++++++++++++++++++---
For my own reference: Acked-for-MFD-by: Lee Jones <lee.jones@linaro.org>
-- Lee Jones [李琼斯] Linaro Services Technical Lead Linaro.org │ Open source software for ARM SoCs Follow Linaro: Facebook | Twitter | Blog
| |