Messages in this thread | | | Date | Thu, 19 Jul 2018 12:23:36 +0200 | From | Johan Hovold <> | Subject | Re: [PATCH v4 1/4] rtc: omap: Cut down the shutdown time from 2 seconds to 1 sec |
| |
On Thu, Jul 12, 2018 at 10:37:37AM +0530, Keerthy wrote: > Cut down the shutdown time from 2 seconds to 1 sec. In case of roll > over try again. > > Signed-off-by: Keerthy <j-keerthy@ti.com>
> @@ -435,17 +435,23 @@ static void omap_rtc_power_off(void)
> + /* set alarm one second from now */ > omap_rtc_read_time_raw(rtc, &tm); > + seconds = tm.tm_sec; > bcd2tm(&tm); > rtc_tm_to_time(&tm, &now); > - rtc_time_to_tm(now + 2, &tm); > + rtc_time_to_tm(now + 1, &tm);
One more thing, the comment before final mdelay as well as that delay itself also needs to be updated to reflect this change.
Thanks, Johan
| |