Subject[PATCH] of: thermal: Allow multiple devices to share cooling map
Date
A cooling map entry may now contain a list of phandles and their
arguments representing multiple devices which share the trip point.

This patch updates the thermal OF core to parse them properly.

Tested on Hikey960.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
---
This is a follow up patch to the DT bindings patchset:

https://lkml.kernel.org/r/cover.1530766981.git.viresh.kumar@linaro.org

drivers/thermal/of-thermal.c | 140 +++++++++++++++++++++++++----------
1 file changed, 102 insertions(+), 38 deletions(-)

diff --git a/drivers/thermal/of-thermal.c b/drivers/thermal/of-thermal.c
index 977a8307fbb1..79c06c4c861b 100644
--- a/drivers/thermal/of-thermal.c
+++ b/drivers/thermal/of-thermal.c
@@ -19,22 +19,33 @@
/*** Private data structures to represent thermal device tree data ***/

/**
- * struct __thermal_bind_param - a match between trip and cooling device
+ * struct __thermal_cooling_bind_param - a cooling device for a trip point
* @cooling_device: a pointer to identify the referred cooling device
- * @trip_id: the trip point index
- * @usage: the percentage (from 0 to 100) of cooling contribution
* @min: minimum cooling state used at this trip point
* @max: maximum cooling state used at this trip point
*/

-struct __thermal_bind_params {
+struct __thermal_cooling_bind_param {
struct device_node *cooling_device;
- unsigned int trip_id;
- unsigned int usage;
unsigned long min;
unsigned long max;
};

+/**
+ * struct __thermal_bind_param - a match between trip and cooling device
+ * @tcbp: a pointer to an array of cooling devices
+ * @count: number of elements in array
+ * @trip_id: the trip point index
+ * @usage: the percentage (from 0 to 100) of cooling contribution
+ */
+
+struct __thermal_bind_params {
+ struct __thermal_cooling_bind_param *tcbp;
+ unsigned int count;
+ unsigned int trip_id;
+ unsigned int usage;
+};
+
/**
* struct __thermal_zone - internal representation of a thermal zone
* @mode: current thermal zone device mode (enabled/disabled)
@@ -192,25 +203,31 @@ static int of_thermal_bind(struct thermal_zone_device *thermal,
struct thermal_cooling_device *cdev)
{
struct __thermal_zone *data = thermal->devdata;
- int i;
+ struct __thermal_bind_params *tbp;
+ struct __thermal_cooling_bind_param *tcbp;
+ int i, j;

if (!data || IS_ERR(data))
return -ENODEV;

/* find where to bind */
for (i = 0; i < data->num_tbps; i++) {
- struct __thermal_bind_params *tbp = data->tbps + i;
+ tbp = data->tbps + i;

- if (tbp->cooling_device == cdev->np) {
- int ret;
+ for (j = 0; j < tbp->count; j++) {
+ tcbp = tbp->tcbp + j;

- ret = thermal_zone_bind_cooling_device(thermal,
+ if (tcbp->cooling_device == cdev->np) {
+ int ret;
+
+ ret = thermal_zone_bind_cooling_device(thermal,
tbp->trip_id, cdev,
- tbp->max,
- tbp->min,
+ tcbp->max,
+ tcbp->min,
tbp->usage);
- if (ret)
- return ret;
+ if (ret)
+ return ret;
+ }
}
}

@@ -221,22 +238,28 @@ static int of_thermal_unbind(struct thermal_zone_device *thermal,
struct thermal_cooling_device *cdev)
{
struct __thermal_zone *data = thermal->devdata;
- int i;
+ struct __thermal_bind_params *tbp;
+ struct __thermal_cooling_bind_param *tcbp;
+ int i, j;

if (!data || IS_ERR(data))
return -ENODEV;

/* find where to unbind */
for (i = 0; i < data->num_tbps; i++) {
- struct __thermal_bind_params *tbp = data->tbps + i;
+ tbp = data->tbps + i;
+
+ for (j = 0; j < tbp->count; j++) {
+ tcbp = tbp->tcbp + j;

- if (tbp->cooling_device == cdev->np) {
- int ret;
+ if (tcbp->cooling_device == cdev->np) {
+ int ret;

- ret = thermal_zone_unbind_cooling_device(thermal,
- tbp->trip_id, cdev);
- if (ret)
- return ret;
+ ret = thermal_zone_unbind_cooling_device(thermal,
+ tbp->trip_id, cdev);
+ if (ret)
+ return ret;
+ }
}
}

@@ -652,8 +675,9 @@ static int thermal_of_populate_bind_params(struct device_node *np,
int ntrips)
{
struct of_phandle_args cooling_spec;
+ struct __thermal_cooling_bind_param *__tcbp;
struct device_node *trip;
- int ret, i;
+ int ret, i, count;
u32 prop;

/* Default weight. Usage is optional */
@@ -680,20 +704,44 @@ static int thermal_of_populate_bind_params(struct device_node *np,
goto end;
}

- ret = of_parse_phandle_with_args(np, "cooling-device", "#cooling-cells",
- 0, &cooling_spec);
- if (ret < 0) {
+ count = of_count_phandle_with_args(np, "cooling-device",
+ "#cooling-cells");
+ if (!count) {
pr_err("missing cooling_device property\n");
goto end;
}
- __tbp->cooling_device = cooling_spec.np;
- if (cooling_spec.args_count >= 2) { /* at least min and max */
- __tbp->min = cooling_spec.args[0];
- __tbp->max = cooling_spec.args[1];
- } else {
- pr_err("wrong reference to cooling device, missing limits\n");
+
+ __tcbp = kcalloc(count, sizeof(*__tcbp), GFP_KERNEL);
+ if (!__tcbp)
+ goto end;
+
+ for (i = 0; i < count; i++) {
+ ret = of_parse_phandle_with_args(np, "cooling-device",
+ "#cooling-cells", i, &cooling_spec);
+ if (ret < 0) {
+ pr_err("missing cooling_device property\n");
+ goto free_tcbp;
+ }
+
+ __tcbp[i].cooling_device = cooling_spec.np;
+
+ if (cooling_spec.args_count >= 2) { /* at least min and max */
+ __tcbp[i].min = cooling_spec.args[0];
+ __tcbp[i].max = cooling_spec.args[1];
+ } else {
+ pr_err("wrong reference to cooling device, missing limits\n");
+ }
}

+ __tbp->tcbp= __tcbp;
+ __tbp->count = count;
+
+ goto end;
+
+free_tcbp:
+ for (i = i - 1; i >= 0; i--)
+ of_node_put(__tcbp[i].cooling_device);
+ kfree(__tcbp);
end:
of_node_put(trip);

@@ -900,8 +948,16 @@ __init *thermal_of_build_thermal_zone(struct device_node *np)
return tz;

free_tbps:
- for (i = i - 1; i >= 0; i--)
- of_node_put(tz->tbps[i].cooling_device);
+ for (i = i - 1; i >= 0; i--) {
+ struct __thermal_bind_params *tbp = tz->tbps + i;
+ int j;
+
+ for (j = 0; j < tbp->count; j++)
+ of_node_put(tbp->tcbp[j].cooling_device);
+
+ kfree(tbp->tcbp);
+ }
+
kfree(tz->tbps);
free_trips:
for (i = 0; i < tz->ntrips; i++)
@@ -917,10 +973,18 @@ __init *thermal_of_build_thermal_zone(struct device_node *np)

static inline void of_thermal_free_zone(struct __thermal_zone *tz)
{
- int i;
+ struct __thermal_bind_params *tbp;
+ int i, j;
+
+ for (i = 0; i < tz->num_tbps; i++) {
+ tbp = tz->tbps + i;
+
+ for (j = 0; j < tbp->count; j++)
+ of_node_put(tbp->tcbp[j].cooling_device);
+
+ kfree(tbp->tcbp);
+ }

- for (i = 0; i < tz->num_tbps; i++)
- of_node_put(tz->tbps[i].cooling_device);
kfree(tz->tbps);
for (i = 0; i < tz->ntrips; i++)
of_node_put(tz->trips[i].np);
--
2.18.0.rc1.242.g61856ae69a2c
\
 
 \ /