Messages in this thread | | | Date | Thu, 28 Jun 2018 19:55:51 -0700 | From | Guenter Roeck <> | Subject | Re: [v4, 2/6] Documentation: DT: Add optional 'timeout-sec' property for sp805 |
| |
On Mon, May 28, 2018 at 11:01:33AM -0700, Ray Jui wrote: > Update the SP805 binding document to add optional 'timeout-sec' > devicetree property > > Signed-off-by: Ray Jui <ray.jui@broadcom.com> > Reviewed-by: Rob Herring <robh@kernel.org>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
> --- > Documentation/devicetree/bindings/watchdog/arm,sp805.txt | 2 ++ > 1 file changed, 2 insertions(+) > > diff --git a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt > index 0fa3629..bee6f1f 100644 > --- a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt > +++ b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt > @@ -19,6 +19,8 @@ Required properties: > > Optional properties: > - interrupts: Should specify WDT interrupt number > +- timeout-sec: Should specify default WDT timeout in seconds. If unset, the > + default timeout is determined by the driver > > Example: > watchdog@66090000 {
| |