Messages in this thread | | | Date | Thu, 24 May 2018 10:12:29 -0700 | From | Guenter Roeck <> | Subject | Re: [PATCH v3 2/6] Documentation: DT: Add optional 'timeout-sec' property for sp805 |
| |
On Thu, May 24, 2018 at 09:42:20AM -0700, Ray Jui wrote: > > > On 5/24/2018 9:16 AM, Guenter Roeck wrote: > >On Wed, May 23, 2018 at 05:15:20PM -0700, Ray Jui wrote: > >>Update the SP805 binding document to add optional 'timeout-sec' > >>devicetree property > >> > >>Signed-off-by: Ray Jui <ray.jui@broadcom.com> > >>--- > >> Documentation/devicetree/bindings/watchdog/arm,sp805.txt | 2 ++ > >> 1 file changed, 2 insertions(+) > >> > >>diff --git a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt > >>index 0fa3629..1debea3 100644 > >>--- a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt > >>+++ b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt > >>@@ -19,6 +19,8 @@ Required properties: > >> Optional properties: > >> - interrupts: Should specify WDT interrupt number > >>+- timeout-sec: Should specify default WDT timeout in seconds. If unset, the > >>+ default timeout in the driver is 30 seconds > > > >"... the default timeout is determined by the driver" might be better. > >If you want to mandate a default here (not sure if that is a good idea), > >I would suggest to use something like "should be 30 seconds". > > > > Okay. This can be changed to: > > - timeout-sec: Should specify default WDT timeout in seconds. If unset, the > default timeout is determined by the driver. > > Please advise how to proceed with this patch series. Should I make the above > modification and send out v4?
I would suggest to wait a day or two, then send out v4 if there are no further comments.
Thanks, Guenter
| |