Messages in this thread | | | From | Heiko Stübner <> | Subject | Re: [PATCH v3 04/13] soc: rockchip: power-domain: Fix wrong value when power up pd | Date | Wed, 23 May 2018 12:57:38 +0200 |
| |
Am Mittwoch, 23. Mai 2018, 08:48:40 CEST schrieb Elaine Zhang: > From: Finley Xiao <finley.xiao@rock-chips.com> > > Solve the pd could only ever turn off but never turn them on again, > If the pd registers have the writemask bits. > > Fix up the code error for commit: > commit 79bb17ce8edb3141339b5882e372d0ec7346217c > Author: Elaine Zhang <zhangqing@rock-chips.com> > Date: Fri Dec 23 11:47:52 2016 +0800 > > soc: rockchip: power-domain: Support domain control in hiword-registers > > New Rockchips SoCs may have their power-domain control in registers > using a writemask-based access scheme (upper 16bit being the write > mask). So add a DOMAIN_M type and handle this case accordingly. > Signed-off-by: Elaine Zhang <zhangqing@rock-chips.com> > Signed-off-by: Heiko Stuebner <heiko@sntech.de> > > Signed-off-by: Finley Xiao <finley.xiao@rock-chips.com> > Signed-off-by: Elaine Zhang <zhangqing@rock-chips.com>
I've already applied that patch from v2.
Heiko
| |