On 4/18/2018 7:32 AM, Rob Herring wrote: > On Tue, Apr 17, 2018 at 3:40 PM, Jae Hyun Yoo > <jae.hyun.yoo@linux.intel.com> wrote: >> On 4/16/2018 4:51 PM, Jae Hyun Yoo wrote: >>> >>> On 4/16/2018 4:22 PM, Jae Hyun Yoo wrote: >>>> >>>> On 4/16/2018 11:14 AM, Rob Herring wrote: >>>>> >>>>> On Tue, Apr 10, 2018 at 11:32:09AM -0700, Jae Hyun Yoo wrote: >>>>>> >>>>>> This commit adds dt-bindings documents for PECI cputemp and dimmtemp >>>>>> client >>>>>> drivers. >>>>> >>>>> >> >> [...] >> >>>>>> +Example: >>>>>> + peci-bus@0 { >>>>>> + #address-cells = <1>; >>>>>> + #size-cells = <0>; >>>>>> + < more properties > >>>>>> + >>>>>> + peci-dimmtemp@cpu0 { >>>>> >>>>> >>>>> unit-address is wrong. >>>>> >>>> >>>> Will fix it using the reg value. >>>> >>>>> It is a different bus from cputemp? Otherwise, you have conflicting >>>>> addresses. If that's the case, probably should make it clear by showing >>>>> different host adapters for each example. >>>>> >>>> >>>> It could be the same bus with cputemp. Also, client address sharing is >>>> possible by PECI core if the functionality is different. I mean, cputemp and >>>> dimmtemp targeting the same client is possible case like this. >>>> peci-cputemp@30 >>>> peci-dimmtemp@30 >>>> >>> >>> Oh, I got your point. Probably, I should change these separate settings >>> into one like >>> >>> peci-client@30 { >>> compatible = "intel,peci-client"; >>> reg = <0x30>; >>> }; >>> >>> Then cputemp and dimmtemp drivers could refer the same compatible string. >>> Will rewrite it. >>> >> >> I've checked it again and realized that it should use function based node >> name like: >> >> peci-cputemp@30 >> peci-dimmtemp@30 >> >> If it use the same string like 'peci-client@30', the drivers cannot be >> selectively enabled. The client address sharing way is well handled in PECI >> core and this way would be better for the future implementations of other >> PECI functional drivers such as crash dump driver and so on. So I'm going >> change the unit-address only. > > 2 nodes at the same address is wrong (and soon dtc will warn you on > this). You have 2 potential options. The first is you need additional > address information in the DT if these are in fact 2 independent > devices. This could be something like a function number to use > something from PCI addressing. From what I found on PECI, it doesn't > seem to have anything like that. The 2nd option is you have a single > DT node which registers multiple hwmon devices. DT nodes and drivers > don't have to be 1-1. Don't design your DT nodes from how you want to > partition drivers in some OS. > > Rob >
Please correct me if I'm wrong but I'm still thinking that it is possible. Also, I did compile it but dtc doesn't make a warning. Let me show an another use case which is similar to this case:
In arch/arm/boot/dts/aspeed-g5.dtsi [...] lpc_host: lpc-host@80 { compatible = "aspeed,ast2500-lpc-host", "simple-mfd", "syscon"; reg = <0x80 0x1e0>; reg-io-width = <4>;
#address-cells = <1>; #size-cells = <1>; ranges = <0x0 0x80 0x1e0>;
lpc_ctrl: lpc-ctrl@0 { compatible = "aspeed,ast2500-lpc-ctrl"; reg = <0x0 0x80>; clocks = <&syscon ASPEED_CLK_GATE_LCLK>; status = "disabled"; };
lpc_snoop: lpc-snoop@0 { compatible = "aspeed,ast2500-lpc-snoop"; reg = <0x0 0x80>; interrupts = <8>; status = "disabled"; }; } [...]
This is device tree setting for LPC interface and its child nodes. LPC interface can be used as a multi-functional interface such as snoop 80, KCS, SIO and so on. In this use case, lpc-ctrl@0 and lpc-snoop@0 are sharing their address range from their individual driver modules and they can be registered quite well through both static dt or dynamic dtoverlay. PECI is also a multi-functional interface which is similar to the above case, I think.
Thanks,
Jae
|  |