lkml.org 
[lkml]   [2018]   [Apr]   [18]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
From
Date
SubjectRe: [PATCH v3 07/10] Documentation: dt-bindings: Add documents for PECI hwmon client drivers
On Tue, Apr 17, 2018 at 3:40 PM, Jae Hyun Yoo
<jae.hyun.yoo@linux.intel.com> wrote:
> On 4/16/2018 4:51 PM, Jae Hyun Yoo wrote:
>>
>> On 4/16/2018 4:22 PM, Jae Hyun Yoo wrote:
>>>
>>> On 4/16/2018 11:14 AM, Rob Herring wrote:
>>>>
>>>> On Tue, Apr 10, 2018 at 11:32:09AM -0700, Jae Hyun Yoo wrote:
>>>>>
>>>>> This commit adds dt-bindings documents for PECI cputemp and dimmtemp
>>>>> client
>>>>> drivers.
>>>>
>>>>
>
> [...]
>
>>>>> +Example:
>>>>> + peci-bus@0 {
>>>>> + #address-cells = <1>;
>>>>> + #size-cells = <0>;
>>>>> + < more properties >
>>>>> +
>>>>> + peci-dimmtemp@cpu0 {
>>>>
>>>>
>>>> unit-address is wrong.
>>>>
>>>
>>> Will fix it using the reg value.
>>>
>>>> It is a different bus from cputemp? Otherwise, you have conflicting
>>>> addresses. If that's the case, probably should make it clear by showing
>>>> different host adapters for each example.
>>>>
>>>
>>> It could be the same bus with cputemp. Also, client address sharing is
>>> possible by PECI core if the functionality is different. I mean, cputemp and
>>> dimmtemp targeting the same client is possible case like this.
>>> peci-cputemp@30
>>> peci-dimmtemp@30
>>>
>>
>> Oh, I got your point. Probably, I should change these separate settings
>> into one like
>>
>> peci-client@30 {
>> compatible = "intel,peci-client";
>> reg = <0x30>;
>> };
>>
>> Then cputemp and dimmtemp drivers could refer the same compatible string.
>> Will rewrite it.
>>
>
> I've checked it again and realized that it should use function based node
> name like:
>
> peci-cputemp@30
> peci-dimmtemp@30
>
> If it use the same string like 'peci-client@30', the drivers cannot be
> selectively enabled. The client address sharing way is well handled in PECI
> core and this way would be better for the future implementations of other
> PECI functional drivers such as crash dump driver and so on. So I'm going
> change the unit-address only.

2 nodes at the same address is wrong (and soon dtc will warn you on
this). You have 2 potential options. The first is you need additional
address information in the DT if these are in fact 2 independent
devices. This could be something like a function number to use
something from PCI addressing. From what I found on PECI, it doesn't
seem to have anything like that. The 2nd option is you have a single
DT node which registers multiple hwmon devices. DT nodes and drivers
don't have to be 1-1. Don't design your DT nodes from how you want to
partition drivers in some OS.

Rob

\
 
 \ /
  Last update: 2018-04-18 16:34    [W:0.083 / U:0.136 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site