    SubjectRe: [PATCH 01/14] thermal: exynos: Reading temperature makes sense only when TMU is turned on
    Date
    On Monday, April 16, 2018 02:06:41 PM Daniel Lezcano wrote:
    > On 16/04/2018 12:11, Bartlomiej Zolnierkiewicz wrote:
    > > From: Marek Szyprowski <m.szyprowski@samsung.com>
    > >
    > > When thermal sensor is not yet enabled, reading temperature might return
    > > random value. This might even result in stopping system booting when such
    > > temperature is higher than the critical value. Fix this by checking if TMU
    > > has been actually enabled before reading the temperature.
    > >
    > > This change fixes booting of Exynos4210-based board with TMU enabled (for
    > > example Samsung Trats board), which was broken since v4.4 kernel release.
    >
    > Why not move the thermal_zone_of_sensor_register *after* initializing
    > the sensor ?

    For initializing the sensor we need data obtained from
    therm_zone_of_sensor_register() so it cannot be easily
    done (especially since we also want the fix to be
    ported to -stable kernels). For more detailed description
    please see:

    https://lkml.org/lkml/2018/4/10/376

    > > Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com>
    > > Fixes: 9e4249b40340 ("thermal: exynos: Fix first temperature read after registering sensor")
    > > CC: stable@vger.kernel.org # v4.6+
    > > Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>

    Best regards,
    --
    Bartlomiej Zolnierkiewicz
    Samsung R&D Institute Poland