Messages in this thread | | | Date | Mon, 16 Apr 2018 10:38:21 +0100 | From | Lee Jones <> | Subject | Re: [PATCH v5 1/2] mfd: rk808: Refactor shutdown functions |
| |
On Thu, 29 Mar 2018, Daniel Schultz wrote:
> Since all three shutdown functions have almost the same code, all logic > from the shutdown functions can be refactored to a new function > "rk808_update_bits", which can update a register by a given address and > bitmask. > > Signed-off-by: Daniel Schultz <d.schultz@phytec.de> > --- > Changes: > v2: Re-submit with recipients from Rockchip. > v3: - Added devicetree property to enable the PMIC reset seperate from > "rockchip,system-power-controller". > - Dropped the first patch of this serie. > v4: Splitted refactoring and the new reset feature. > v5: Removed null pointer from rk808_update_bits. > > drivers/mfd/rk808.c | 46 +++++++++++++--------------------------------- > 1 file changed, 13 insertions(+), 33 deletions(-)
I'd still like an Ack/Review from the Rockchip guys please.
-- Lee Jones [李琼斯] Linaro Services Technical Lead Linaro.org │ Open source software for ARM SoCs Follow Linaro: Facebook | Twitter | Blog
| |