On Mon 2018-03-26 11:52:09, Enric Balletbo i Serra wrote:
> Before this patch the enable signal was set before the PWM signal and
> vice-versa on power off. This sequence is wrong, at least, it is on
> the different panels datasheets that I checked, so I inverted the sequence
> to follow the specs.
>
> For reference the following panels have the mentioned sequence:
> - N133HSE-EA1 (Innolux)
> - N116BGE (Innolux)
> - N156BGE-L21 (Innolux)
> - B101EAN0 (Auo)
> - B101AW03 (Auo)
> - LTN101NT05 (Samsung)
> - CLAA101WA01A (Chunghwa)

Ok, but this changes behaviour for other panels, too. Are you sure you
are not breaking one of those?