SubjectRe: [PATCH v11 04/10] clocksource: timer-ti-dm: Replace architecture
From
Date


On Friday 23 February 2018 12:15 AM, Tony Lindgren wrote:
> * Ladislav Michl <ladis@linux-mips.org> [180222 10:58]:
>> On Thu, Feb 15, 2018 at 11:31:45AM +0530, Keerthy wrote:
>>> Replace architecture specific guard with clocksource guard.
>>>
>>> Signed-off-by: Keerthy <j-keerthy@ti.com>
>>> Replace architecture specific defines with clocksource
>>
>> This looks like a bit unussual commit log. Also, what about merging
>> it with previous patch?
>
> I'll just remove that line locally to avoid yet another set
> of patches being posted :)

Thanks!

>
>> Btw, I tested whole serie again on the top of today's -next and it is
>> still working fine. What is preventing these patches from being merged?

Ladis,

Thanks once again.


>
> Well I noticed we need a fix for omap1 that I just posted.
> And patch 4/10 needs the following select for omap16xx that
> I'll fold in.
>
> I'll push it all to omap-for-v4.17/timer and will merge into
> my for-next after some more testing. It seems any further
> patching can be done after move to drivers.

Yes that would be great.

>
> Regards,
>
> Tony
>
> 8< -----------------
> --- a/arch/arm/mach-omap1/Kconfig
> +++ b/arch/arm/mach-omap1/Kconfig
> @@ -30,6 +30,7 @@ config ARCH_OMAP16XX
> bool "OMAP16xx Based System"
> select ARCH_OMAP_OTG
> select CPU_ARM926T
> + select OMAP_DM_TIMER
>
> config OMAP_MUX
> bool "OMAP multiplexing support"
>

\
 
 \ /