SubjectRe: [PATCH 1/3] dt-bindings: mfd: syscon: Add optional clock support
On Tue, Nov 27, 2018 at 05:48:15PM +0100, Fabrice Gasnier wrote:
> Some system control registers need to be clocked, so the registers can
> be accessed. Add an optional clock.
>
> Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com>
> ---
> Documentation/devicetree/bindings/mfd/syscon.txt | 1 +
> 1 file changed, 1 insertion(+)
>
> diff --git a/Documentation/devicetree/bindings/mfd/syscon.txt b/Documentation/devicetree/bindings/mfd/syscon.txt
> index 25d9e9c..a9aaa51 100644
> --- a/Documentation/devicetree/bindings/mfd/syscon.txt
> +++ b/Documentation/devicetree/bindings/mfd/syscon.txt
> @@ -17,6 +17,7 @@ Optional property:
> - reg-io-width: the size (in bytes) of the IO accesses that should be
> performed on the device.
> - hwlocks: reference to a phandle of a hardware spinlock provider node.
> +- clocks: phandle to the syscon clock

No. Add clocks to specific bindings using syscon. If you have a node
with only 'syscon', then that should be fixed.

Rob

\
 
 \ /