Messages in this thread | | | Subject | Re: [PATCH v4] video: fbdev: omapfb: lcd_ams_delta: use GPIO lookup table | From | Bartlomiej Zolnierkiewicz <> | Date | Mon, 8 Oct 2018 12:50:21 +0200 |
| |
On 10/03/2018 03:03 PM, Janusz Krzysztofik wrote: > Now as Amstrad Delta board - the only user of this driver - provides > GPIO lookup tables, switch from GPIO numbers to GPIO descriptors and > use the table to locate required GPIO pins. > > Declare static variables for storing GPIO descriptors and replace > gpio_ function calls with their gpiod_ equivalents. Move GPIO lookup > to the driver probe function so device initialization can be deferred > instead of aborted if a GPIO pin is not yet available. > > Pin naming used by the driver should be followed while respective GPIO > lookup table is initialized by a board init code. > > Signed-off-by: Janusz Krzysztofik <jmkrzyszt@gmail.com> > Reviewed-by: Linus Walleij <linus.walleij@linaro.org>
Patch queued for 4.20, thanks.
Best regards, -- Bartlomiej Zolnierkiewicz Samsung R&D Institute Poland Samsung Electronics
| |