SubjectRe: [PATCH 2/2] cdc-acm: correct counting of UART states in serial state notification
From
Date
On Sa, 2018-09-22 at 22:11 +0200, Tobias Herzog wrote:
> The usb standard ("Universal Serial Bus Class Definitions for Communication
> Devices") distiguishes between "consistent signals" (DSR, DCD), and
> "irregular signals" (break, ring, parity error, framing error, overrun).
> The bits of "irregular signals" are set, if this error/event occurred on
> the device side and are immeadeatly unset, if the serial state notification
> was sent.
> Like other drivers of real serial ports do, just the occurence of those
> events should be counted in serial_icounter_struct (but no 1->0
> transitions).
>
> Signed-off-by: Tobias Herzog <t-herzog@gmx.de>
Acked-by: Oliver Neukum <oneukum@suse.com>

\
 
 \ /
  Last update: 2018-10-04 15:35    [W:0.027 / U:0.052 seconds]