On Sat, May 14, 2016 at 10:36:38PM +0300, Sergei Shtylyov wrote:
> Hello.
>
> On 05/14/2016 02:44 AM, Andrew Lunn wrote:
>
> >>>>>Another issue is that on some boards we have one reset line tied to
> >>>>>multiple PHYs.How do we prevent multiple resets being taking place when each of
> >>>>>the PHYs are registered?
> >>>>
> >>>> My patch just doesn't address this case -- it's about the
> >>>>individual resets only.
> >>>
> >>>This actually needs to be addresses a layer above. What you have is a
> >>>bus reset, not a device reset.
> >>
> >> No.
> >> There's simply no such thing as a bus reset for the xMII/MDIO
> >>busses, there's simply no reset signaling on them. Every device has
> >>its own reset signal and its own timing requirements.
> >
> >Except in the case above, where two phys are sharing the same reset
> >signal. So although it is not part of the mdio standard to have a bus
> >reset, this is in effect what the gpio line is doing, resetting all
> >devices on the bus. If you don't model that as a bus reset, how do you
> >model it?
>
> I'm not suggesting that the shared reset should be handled by my
> patch. Contrariwise, I suggested to use the mii_bus::reset() method

I think we miss understood each other somewhere.

Your code is great for one gpio reset line for one phy.

I think there could be similar code one layer above to handle one gpio
line for multiple phys.

Andrew

\
 
 \ /