lkml.org 
[lkml]   [2016]   [Mar]   [31]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH 1/2] regulator: DT: Add support to scale ramp delay based on platform behavior

On Friday 01 April 2016 12:52 AM, Mark Brown wrote:
> * PGP Signed by an unknown key
>
> On Fri, Apr 01, 2016 at 12:29:05AM +0530, Laxman Dewangan wrote:
>> On Friday 01 April 2016 12:29 AM, Mark Brown wrote:
>> But here is the stuff without typo ;-)
>> Device supports 5mV/us and 100mV/us which is not in observed value.
> So why doesn't the device end up configuring 100mV/us when asked for
> 50mv/us? That's reasonably expected - the configured ramp rate is a
> maximum rate given that this is used to limit inrush current.
>
>

We did this to adjust device configuration to nearest higher side but
this is not working well on some of cases.

On same device, DCDC (SD) rails support 4 ramp configurations,
13.75mV/us, 27.5mV/us, 55mV/us and 100mV/us.

HW team measured the ramp time at 7.5mV/us when device configured at
27.5mV/uS.

So as per above, it will be adjusted to 13.75mV/us (nearest higher side)
for device configuration but this device need to configure for 27.5mV/us.

\
 
 \ /
  Last update: 2016-03-31 22:21    [W:0.078 / U:0.060 seconds]