Messages in this thread | ![/](/images/icornerl.gif) | | Date | Fri, 1 Apr 2016 00:09:18 +0530 | From | Laxman Dewangan <> | Subject | Re: [PATCH 1/2] regulator: DT: Add support to scale ramp delay based on platform behavior |
| |
On Friday 01 April 2016 12:15 AM, Mark Brown wrote: > * PGP Signed by an unknown key > > On Fri, Apr 01, 2016 at 12:01:19AM +0530, Laxman Dewangan wrote: >> On Friday 01 April 2016 12:01 AM, Mark Brown wrote: >>> So the PMIC actually has a setting for the rate you're seeing but for >>> some resaon you can't use it? >> PMIC has the different rate setting what I am seeing on platform (measured). >> HW team measured the ramp dealy with specific configuration of rate setting >> on PMIC which is not default (OTP-One time programmed from Vendor). > That doesn't tell me what happens if you just configure the device to > deliver the rate you're observing...
The setting for observed value is not there for device configuration.
Device support 5mV/us and 100mV/us.
We observed 50mV/us when setting device to 100mV/us.
| ![\](/images/icornerr.gif) |