Messages in this thread | | | From | "Matwey V. Kornilov" <> | Date | Wed, 10 Feb 2016 19:24:02 +0300 | Subject | Re: [PATCH v8 0/3] tty: Introduce software RS485 direction control support |
| |
2016-02-10 19:05 GMT+03:00 Peter Hurley <peter@hurleysoftware.com>: > Hi Matwey, > > On 02/01/2016 10:09 AM, Matwey V. Kornilov wrote: >> Changes from v7: >> - rework comments to follow guidelines >> - minor style changes >> Changes from v6: >> - minor style changes >> - timers are not IRQSAFE now >> Changes from v5: >> - rs485_emul variable has been renamed to em485 to follow function names convention >> Changes from v4: >> - Add commit message to 1/3 >> Changes from v3: >> - Completely redesigned. >> Changes from v2: >> - Introduced SER_RS485_SOFTWARE to show that software implementation is being used >> - serial8250_rs485_config is located as required >> - Timers are used to implement delay_before and delay_after timeouts >> >> Signed-off-by: Matwey V. Kornilov <matwey@sai.msu.ru> > > The holdup here is that I'd like to unit test this, which is 3rd on my todo list. > Should be done before the end of the week which will be soon enough > for this series to make linux-next.
Hi Peter,
Is something required from me?
> > Thanks for your work on this. > > Regards, > Peter Hurley >
-- With best regards, Matwey V. Kornilov. Sternberg Astronomical Institute, Lomonosov Moscow State University, Russia 119991, Moscow, Universitetsky pr-k 13, +7 (495) 9392382
| |