On Mon, Jul 06, 2015 at 08:09:08AM +0100, Ma Jun wrote: > Add the mbigen msi interrupt controller bindings document > > Change in v3: > ---Change the compatible string > ---Change the interrupt cells definition. > > Signed-off-by: Ma Jun <majun258@huawei.com> > --- > Documentation/devicetree/bindings/arm/mbigen.txt | 65 ++++++++++++++++++++++ > 1 files changed, 65 insertions(+), 0 deletions(-) > create mode 100644 Documentation/devicetree/bindings/arm/mbigen.txt > > diff --git a/Documentation/devicetree/bindings/arm/mbigen.txt b/Documentation/devicetree/bindings/arm/mbigen.txt > new file mode 100644 > index 0000000..cf92ef8 > --- /dev/null > +++ b/Documentation/devicetree/bindings/arm/mbigen.txt > @@ -0,0 +1,65 @@ > +Hisilicon mbigen device tree bindings. > +======================================= > + > +Mbigen means: message based interrupt generator. > + > +MBI is kind of msi interrupt only used on Non-PCI devices. > + > +To reduce the wired interrupt number connected to GIC, > +Hisilicon designed mbigen to collect and generate interrupt. > + > + > +Non-pci devices can connect to mbigen and gnerate the inteerrupt > +by wirtting ITS register.
Please run this through a spell checker to get rid of typos.
> + > +The mbigen and devices connect to mbigen have the following properties: > + > + > +Mbigen required properties: > +------------------------------------------- > +-compatible: Should be "hisilicon,mbigen-v2" > +-msi-parent: should specified the ITS mbigen connected > +-interrupt controller: Identifies the node as an interrupt controller > +- #interrupt-cells : Specifies the number of cells needed to encode an > + interrupt source. The value is 5 now. > + > + The 1st cell is the device id.
Does a given mbigen block generate interrupts with different ITS device IDs? Or does a given mbigen block have a single device ID shared by all interrupts it generates?
> + The 2nd cell is the totall interrupt number of this device?
I don't follow. What is a "total interrupt number"?
> + The 3rd cell is the hardware pin number of the interrupt. > + This value depends on the Soc design.
This property seems sane.
> + The 4th cell is the mbigen node number. This value should refer to the > + vendor soc specification.
What is this, and why do you think you need it?
Surely the address of the mbigen node is a sufficient unique identifier?
> + The 5th cell is the interrupt trigger type, encoded as follows: > + 1 = edge triggered > + 4 = level triggered
Hmm. How are level-triggered interrupts expected to be handled by the mbigen?
> + > +- reg: Specifies the base physical address and size of the ITS > + registers.
NAK. You should not describe ITS properties here given this is not the ITS.
Perhaps you mean "the mbigen registers"?
Thanks, Mark.
| |